摘要
随着UPS电源系统负荷的快速增长,UPS的可靠性显得尤为重要。文中结合工程实例,介绍了500 kV变电站UPS不间断电源系统改造方案和改造中的关键技术,通过改造提高其在各种突发性事故中的可靠性,为有类似不符合规范的UPS系统改造提供借鉴。
With the rapid growth of UPS power system load, the reliability of UPS is very particularly important. Combining with engineering practice, this paper introduced the 500 kV substation reconstruction scheme of UPS uninterruptible power supply system and key technology in the transformation, improved the reliability in various sudden incidents to provide a reference for similar non-compliant UPS system transformation.
出处
《通信电源技术》
2012年第4期104-105,109,共3页
Telecom Power Technology
关键词
变电站
UPS
电源
改造
substation
UPS
power supply
transformation