期刊文献+

一体化空调在3G基站的应用 被引量:1

The Application of Integrated Air-Conditioning in the 3G Base Station
下载PDF
导出
摘要 随着C网运营承接,如何在确保C网安全运行的前提下,稳妥推进基站节能技术应用,是当前面临的新问题。文中通过对3G基站空调的配置要求及使用现状的介绍,阐述了基站一体化空调的工作原理和特点,提出了基站节能、防盗的解决方案,论证了一体化空调在基站使用的实用性。 With the undertaking of C network operation, it is the current new problems how to steadily push forward the base station energy-saving technology under the premise of ensuring the safe operation of the C network. Through the introduction of configuration requirements for 3G base stations air-conditioning, the working principle and characteristics of the base station integrated air-conditioning are described; the base station energy saving and anti-theft solutions are put forward; the practicality of using the integration of air conditioning in the base station is demonstrated.
作者 吴剑
出处 《通信电源技术》 2012年第4期110-112,共3页 Telecom Power Technology
关键词 节能 一体化空调 舒适性空调 energy-saving, integrated air-conditioning comfort air conditioning