摘要 An ion chromatography method has been proposed for the determination of three common inorganic anions(chloride,nitrate and sulfate) in anionic surfactants using a single pump system.The new system consists of an ion exclusion column,a concentrator column,and an anion exchange column connected in series via two 6-ports valves in a Dionex ICS-2000 ion chromatograph.The valves were switched several times for removing surfactants,concentrating and separating the three anions.The chromatographic conditions were optimized.Detection limits(S/N = 3) were in the range of 0.10-0.68μg/L.The relative standard deviations(RSDs) of peak area were less than 4.6%.The recoveries were in the range of 84.1-112.6%. An ion chromatography method has been proposed for the determination of three common inorganic anions(chloride,nitrate and sulfate) in anionic surfactants using a single pump system.The new system consists of an ion exclusion column,a concentrator column,and an anion exchange column connected in series via two 6-ports valves in a Dionex ICS-2000 ion chromatograph.The valves were switched several times for removing surfactants,concentrating and separating the three anions.The chromatographic conditions were optimized.Detection limits(S/N = 3) were in the range of 0.10-0.68μg/L.The relative standard deviations(RSDs) of peak area were less than 4.6%.The recoveries were in the range of 84.1-112.6%.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第7期835-838,共4页 中国化学快报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.20775070 and J0830413) Zhejiang Provincial Natural Science Foundation of China(Nos.R4080124 and J20091495)
关键词 Anionic surfactants Single pump COLUMN-SWITCHING Anionic surfactants Single pump Column-switching
  • 相关文献

参考文献8

  • 1E. Kaiser, J.S. Rohrer, K. Watanabe, J. Chromatogr. A 850 (1999) 167.
  • 2F.S. Stover, J. Chromatogr. A 956 (2002) 121.
  • 3L.E. Vanatta, D.E. Coleman, J. Chromatogr. A 804 (1998) 161.
  • 4S. Liu, N. Shinkai, I. Kakubari, et al. Biomed. Chromatogr. 22 (2008) 1442.
  • 5V. Ruiz-Calero, L. Puignou, M. Diez, Analyst 126 (2001) 169.
  • 6K. Wang, Y. Lei, M. Eitel, et al. J. Chromatogr. A 956 (2002) 109.
  • 7H.B. Zhu, H.D. Chert, Y.Y. Zhong, J. Chromatogr. Sci. 48 (2010) 553.
  • 8http:llwww.dionex.comlen-uslwebdocs14350-Man-O31333-O8-IonPac-AS l lHC-NovOS.pdf, p. 44.