摘要 目的探讨装载流程再造在降低灭菌器械湿包发生中的作用效果。方法选择2010年10月~2011年1月在本消毒供应中心消毒的3850件纸塑包装的医疗器械包为对照组,2011年2~4月的4050件纸塑包装的医疗器械包为实验组。器械进行灭菌时对照组采用常规装载方法,实验组采用装载流程再造。比较两组湿包发生情况的差异。结果实验组发生湿包有57件(1.41%),对照组有153件(3.97%),两组比较,χ2=50.248,P<0.05,差异具有统计学意义,实验组湿包发生率较对照组低。结论装载流程再造可减少器械灭菌后湿包现象的发生。 Objective To study the effect of standardized packaging flowchart on the reduction of moistening packets by sterilizers. Methods 3 850 paper-plastic packages of metal medical instruments in the sterilization and supply center from October 2010 to April 2011 was set as the control group and another 4050 ones from October 2010 to January 2011 as the experiment group. The routine packaging was used in the control group, and the reconstructed flowchart was used in the experiment group. The two groups were compared in moistening packages by sterilizers. Results In the experiment group, 57 packages were moistened, accounting for 1.41%. In the control, 153 packages were moistened, accounting for 3.98 %. The incidence of moistening packages was significantly lower in experiment group, compared with conventional method (X2 = 50.248, P 〈 0.05 ). Conclusions The reconstructed flowchart for packaging can be effective in reducing the incidence of moistening packages.
出处 《现代临床护理》 2012年第6期66-67,共2页 Modern Clinical Nursing
关键词 器械 消毒 灭菌 流程再造 instrument disinfection sterilization reconstruction of flowchart
  • 相关文献

参考文献7

二级参考文献15

共引文献35

同被引文献28

  • 1张春斐,张红枫,朱亮德,应永芳,沈强,高远西.六西格玛管理方法降低高压蒸汽灭菌后湿包发生率[J].解放军护理杂志,2010,27(2):144-146. 被引量:20
  • 2谭家琼,梅幸福,田桂登.小装载量换药包的临床应用[J].解放军护理杂志,2006,23(4):27-27. 被引量:1
  • 3范玉爽,于涛.消毒供应湿包的控制与研究[C].长春:中华护理学会第7届消毒供应中心发展论坛,2011:330-332.
  • 4张炬峰.医疗器械纸塑包装蒸汽灭菌后湿包的控制与研究[C].长春:中华护理学会第7届消毒供应中心发展论坛,2011:797-798.
  • 5Anderson NM,Walker PN. Quality comparison of contin- uous steam sterilization segmented-flow aseptic process- ing versus conventional canning of whole and sliced mush- rooms[J]. J Food Sci,2011,76(6) :429-437.
  • 6陈瑛.手术器械湿包发生原因分析及对策[C].长沙:中华护理学会第8届全国消毒供应中心发展论坛,2012:63-66.
  • 7McGraw C,Drennan VM. Evaluation of the suitability of root cause analysis frameworks for the investigation of community-acquired pressure ulcers: a systematic review and documentary analysis[J]. J Clin Nuts, 2015,24 (3/4): 536-545.
  • 8刘启华,韩玉芳,窦日华,等.不同装载方法纸塑包装器械压力蒸汽灭菌的比较研究[C].长沙:中华护理学会第8届全国消毒供应中心发展论坛,2012:385-387.
  • 9黄金芳,刘斐,覃雪贤,等.压力蒸汽灭菌隐性湿包的影响因素及控制措施[J].医学信息,2013,26(12):303-304.
  • 10Seyed S, Fayyaz A, Mahshid M. Steam sterilization effect on the accuracy of friction-style mechanical torque limit- ing devices[J]. Indian J Dental Res, 2014, 25 (3) .. 352- 356.