期刊文献+

尾吊大鼠血液细胞电阻抗谱的Cole-Cole模型分析 被引量:5

Analysis of Electrical Impedance Spectroscopy of Blood Cells in Tail-Suspension Rats with Cole-Cole Models
下载PDF
导出
摘要 目的利用Cole-Cole数学模型研究尾吊大鼠血液细胞电阻抗频谱的变化。方法通过非线性数值计算,对血液细胞的Bode图,Nyquist图和Nichols图进行Cole-Cole方程的曲线拟合,比较对照组(Con)与尾吊组(SUS)Cole-Cole模型参数。结果尾吊60 d大鼠血液细胞电阻抗频谱Cole-Cole模型参数变化显示:阻抗高频极限值(R∞)和阻抗增量(ΔR1,ΔR2)减小;特征频率(fC1,fC2)和β驰豫散射角(α1,α2)增加。结论可以通过Cole-Cole数学方程参数表达尾吊大鼠血液细胞电阻抗频谱特性变化。 Objective To study the changes of electrical impedance spectrum (EIS) of blood in tail-suspended rats by using the Cole-Cole mathematical model. Methods The difference in the Cole-Cole model parameters of blood cells were compared between the control group (Con) and the tail suspension group (SUS) with the curve fitting in the Bode diagram, the Nyquist diagram and Nichols diagram by non-linear numerical calcula- tion of the Cole-Cole equation. Results The changes of Cole-Cole model parameters in rats' blood after 60 d tail-suspension were as follows: High-frequency limit of impedance (R∞) and the impedance increment (ΔR1,ΔR2) decreased; the characteristic frequency (α1,α2) and the fl dispersion angle (α1,α2) in- creased. Conclusion The changes of electrical impedance spectral characteristics of blood cells in tail suspen- ded rats can be expressed by the parameters of the Cole-Cole mathematical equation.
出处 《航天医学与医学工程》 CAS CSCD 北大核心 2012年第4期243-246,共4页 Space Medicine & Medical Engineering
基金 宁波市自然科学基金项目(2010A610074)
关键词 尾吊 血液细胞 阻抗频谱 Cole-Cole数学模型 tail-suspension blood cells impedance spectroscopy Cole-Cole mathematical model
  • 相关文献

参考文献10

二级参考文献29

共引文献283

同被引文献47

  • 1赵灵芝,张成孝.交流阻抗法在细胞分析中应用的研究进展[J].化学通报,2015,78(1):23-28. 被引量:4
  • 2鲁勇军,余珏.细胞和组织射频介电弛豫特性分析[J].基础医学与临床,1995,15(3):44-48. 被引量:5
  • 3顾为望,刘运忠,唐小江,王万山,任丽华,吴清洪,林继红,张嘉宁.西藏小型猪血液生理生化指标的初步研究[J].中国实验动物学报,2007,15(1):60-63. 被引量:57
  • 4Qiao GF, Wang W, Duan W, et al. Bioimpedanee analysis for the characterization of breast cancer eells in suspension [J]. IEEE Trans Biomed Eng, 2012, 59(8) : 2321-2329.
  • 5Keshtkar A,Salehnia Z, Keshtkar A, et al. Bladder eaneer detection usingeleetrieal impedance technique ( tabfiz mark 1 ) [J]. Patholog Res Int, 2012, (2012) :470101.
  • 6Zhang D,Zhang Y, Zheng L, et al. Graphene oxide/poly-L- lysineassembled layer for adhesion and eleetroehemieal imped- ance detection of leukemia K562 cancer cells [J]. Biosensors & Bioeleetronies, 2013,42 ( 1 ) : 112 -118.
  • 7Gamal W, Borooah S, Smith S, et al. Real-time quantitative monitoring of hiPSC-based model of maeular degeneration on eleetrie eell-substrate impedance eensing mieroeleetrodes[ J]. Biosens Bioeleetron, 2015, 71(9) : 445-455.
  • 8Scott CW, Peters MF. Label-free whole-cell assays: expan- ding the scope of GPCR screening[ J]. Drug Diseov Today, 2010, 15(17-18) : 704-716.
  • 9Wang L,Wang L,Yin H, et al. Real-time, label-free monito- ring of the cell cycle with a cellular impedance sensing chip [J]. Biosens Bioeleetron, 2010, 25 (5) : 990-995.
  • 10Yang B, Tan Z, Song Y. Study on the molecular regulatory mechanism of MicroRNA-195 in the invasion and metastasis of colorectal carcinoma[J]. Int J Clin Exp Med,2015, 8 (3): 3793 -3800.