摘要
本文通过测量电子密度 ne,电子温度 Te,激发温度 Texc及谱线强度 ,将氢化物进样同水溶液常规气动雾化进样对比 ,研究了氢化物进入 ICP后 ,对等离子体性质的影响。结果表明 ,由于氢化物的引入 。
The effect of hydride on excitation conditions of plasma when hydride was transported by carrier gas into ICP is investigated in this work. After the measurement of the axial electron number densities (n e), electronic temperatures(T e), axial excitation temperatures, it could be concluded that the excitation conditions of ICP was improved resulting from the hydrogen addition effect under the hydride generation.
出处
《分析科学学报》
CAS
CSCD
2000年第3期192-195,共4页
Journal of Analytical Science
关键词
氢化物发生
ICP\AES
等离子体
性质
Excitation conditions
Hydride generation
Inductively coupled plasma atomic emission spectrometry(ICP/AES)