期刊文献+

往复式隔膜计量泵正常运行的几个必须条件 被引量:1

Several Necessary Conditions for Normal Performance of Reciprocating Volume Metering Pump with Diaphragm
下载PDF
导出
摘要 介绍往复式隔膜计量泵在实际工程应用中,需要考虑的三项准则问题,分别为汽蚀、过载和过计量。通过详尽地阐述其相关的原理,提出一些简单可行的解决办法,这些办法通过了实践验证,并有较好的理论支撑,从而为往复式隔膜计量泵在工程应用中能正确的选型和可靠的运行提供一个借鉴。 Three criteria needed to be considered in the application of reciprocating diaphragm pump, which were cavitation, overload and over weighing, were introduced in this article. From the principle of volume metering, some simple and feasible methods were provided. These methods, which are supported with good theories, have been verified in practice, thus, they can be referenced in the selection of reciprocating diaphragm pump in engineering application.
出处 《化工设备与管道》 CAS 2012年第4期44-46,共3页 Process Equipment & Piping
关键词 往复泵 隔膜泵 计量泵 工程应用 rrreciprocating pump diaphragm pump volume metering pump engineering application
  • 相关文献

参考文献5

  • 1查森.叶片泵原理及水力设计[M].哈尔滨:哈尔滨工业大学出版社.1992:83-89.
  • 2LEWA Herbert Ott GmbH+Co.. Meterming Pumps[M].3rd ed. Germany: Verlag moderne industrie. 1997.
  • 3Maschinenbau-Verlag GmbH. NPSH for reciorocation posi- tive displacement pumps[M] 1st ed. Frankfurt: 1989. Bestell Nr.562800.
  • 4全国化工设备设汁技术中心站机泵技术委员会.工业泵选用手册[M].2版.北京:化学工业出版社,2011:207-208.
  • 5FRITSCH H. New results of investigations on the effectiveness of pulsation dampers for high- and low-frequency pressure vibrations[J]. Pumpentagung Karlsruhe, 1988.