摘要
通过对GB 50030-2007《氧气站设计规范》12.0.2中"除氧气管道专用的导电线路外,其他导电线路不得与氧气管道敷设在同一支架上"强制条款的详细解读,对化工工程设计中,经常遇到该条款难以执行的情况,提出了有效、可行的安全措施,有助于秉承规范的安全理念,把事故隐患消除在萌芽中。
With the analysis of the provision 12.0.2 in GB 50030--2007, that is "except any other conductive line shall not be layout with oxygen pipeline on the same support", engineering design, some effective and feasible safety measures were proposed in this removed in its embryonic stage. special conductive line for oxygen pipeline, for the conditions encountered in chemical article. With these measures, perils can be
出处
《化工设备与管道》
CAS
2012年第4期59-60,共2页
Process Equipment & Piping
关键词
管道
导电线路
氧气
净距
pipeline
conductive line
oxygen
distance