两种复合型呼吸过滤器在通气模型中的滤菌效应 被引量:2

Bacteriological Filtration Efficiency of Two Compound Membrane Breathing Filters in Mechanical Model
下载PDF
导出
摘要 目的探讨两种复合型呼吸过滤器(breathing filer,BF)DAR 352/5805(D组)和Vital signs 5708 HE-PA(V组)的滤菌效果。方法用测试液对BF行液体渗透性测试。建立模拟通气环路,对两组BF依次进行3种方法(Ⅰ、Ⅱ、Ⅲ)的测试,通气3 h后,在模拟肺侧、呼吸环路侧、Y型接头内侧采样并孵育24 h。结果随着测试液的加入,V组测试液不断渗入到亲水性滤过膜部分,加入5 ml时可观察到少量蓄积,加入12 ml时,出现测试液明显蓄积且有少量测试液渗入到其疏水膜部分,但测试液未从膜对侧渗出;D组一直表现为测试液不断渗入到亲水性滤过膜中,无测试液渗入到疏水膜中或从滤过膜对侧渗出。模拟机械通气后,V组和D组在采样点模拟肺侧细菌培养均为阳性。在采样点呼吸环路侧和Y型接头内侧,方法Ⅰ中,两组细菌培养均为阴性;方法Ⅱ和Ⅲ中,V组细菌培养均为阳性,D组细菌培养均为阴性,两组比较差异有统计学意义(P<0.05)。结论复合型BF具有明显的滤菌效果;但当滤过膜有液体蓄积时,DAR 352/5805呼吸过滤器的滤菌效应优于Vital signs 5708 HEPA呼吸过滤器。 Objective To compare the efficiency of two compound membrane Breathing Filters(BFs) namely DAR 352/5805(group D) and Vital signs 5708 HEPA(group V) on bacteriological filtration.Methods Liquid permeability test was conducted on BF.The two groups of BFs were tested by three methods(Ⅰ,Ⅱ,Ⅲ) after establishing simulated ventilation hoop.After three hours ventilation,samples were taken from simulated lung,ventilation hoop and inner side of Y joint and then the samples were cultivated for 24 hours.Results With the addition of liquid,the liquid in group V continuously infiltrated into hydrophilic membrane and when the liquid reached 5 ml,a little accumulation was seen.When the liquid reached 12ml,obvious accumulation was seen and a small amount of liquid infiltrated into hydrophobic membrane,but no liquid infiltrated into the opposite side of the membrane.The liquid in group D continuously infiltrated into hydrophilic membrane and no liquid infiltrated into hydrophobic membrane or the opposite side of the membrane.After simulated ventilation,samples of cultivated bacteria from simulated lung were positive both in group V and group D.While samples from ventilation hoop and Y joint by method Ⅰ were both positive in the two groups.While these samples by methods Ⅱ and Ⅲ were positive in group V and were negative in group D.The differences between the two groups were statistically significant(P〈0.05).Conclusion The compound membrane breathing filters have good efficiency on bacteriological filtration.However,when the liquid infiltrates into the hydrophobic membrane,the bacteriological filtration of DAR is better than that of Vital signs.
出处 《中国全科医学》 CAS CSCD 北大核心 2012年第21期2468-2470,共3页 Chinese General Practice
基金 河北省卫生厅青年科技计划(07160)
关键词 呼吸过滤器 机械模型 细菌 Breathing filter Mechanical model Bacterium
  • 相关文献

参考文献12

  • 1Oztoprak N,Cevik MA,Akinci E,et al.Risk factors for ICU-acquired methicillin-resistant staphylococcus aureus infections[J].Am J Infect Control,2006,34(1):1-5.
  • 2刘新平,张秋军,郑瑶.呼吸过滤器在机械通气中的作用[J].中国医疗设备,2008,23(12):83-84. 被引量:5
  • 3高怡,郑劲平.呼吸过滤器在肺功能实验室中的应用[J].国际呼吸杂志,2006,26(11):825-829. 被引量:9
  • 4Vonberg RP,Gastmeier P.Infection control measures in anaesthesia[J].Anasthesiol Intensivmed Notfallmed Schmerzther,2005,40(8):453-458.
  • 5Rees LM,Sheraton TE,Modestini C,et al.Assessing the efficacy of HME filters at preventing contamination of breathing systems[J].Anaesthesia,2007,62(1):67-71.
  • 6李璐,赵砚丽,李建立,张立志,杜彦茹.亲水性和疏水性呼吸过滤器在机械模型中的滤菌作用[J].临床麻醉学杂志,2008,24(4):337-338. 被引量:2
  • 7吕国义,冯雪辛,薛玉良,邓迺封,李雪利.法玛西一次性呼吸环路过滤器滤菌效果观察[J].中华麻醉学杂志,2002,22(9):572-573. 被引量:3
  • 8Cann C,Hampson MA,Wilkes AR,et al.The pressure required to force liquid through breathing system filters[J].Anaesthesia,2006,61(5):492-497.
  • 9Wilkes AR.The effect of gas flow on the filtration performance of breathing system filters[J].Anaesthesia,2004,59(3):278-282.
  • 10Demers RR.Bacterial/viral filtration:let the breather beware![J].Chest,2001,120(4):1377-1389.

二级参考文献44

共引文献16

同被引文献17

  • 1侯艺威,刘小丽,郑吉锋.呼吸过滤器的应用对呼吸参数的影响分析[J].中国医疗器械信息,2004,10(4):24-26. 被引量:5
  • 2高怡,郑劲平.呼吸过滤器在肺功能实验室中的应用[J].国际呼吸杂志,2006,26(11):825-829. 被引量:9
  • 3Torres A,Aznar R,Gatell JM,et al.lncidence,risk,and prognosis factors of nosocomial pneumonia in mechanically ventilated patients[J].Am Rev Respir Dis, 1990;142:523-528.
  • 4Campillo C, Raurich JM,Ibanez J.Length of weaning frommechanical ventilation[J].Surg Clin North Am,2005,31:162.
  • 5Lee MG.Ford JL,Hunt PB.et al.Bacterial retentionproperties of heat and moisture exchange filters[J].Br JAnaesth,1992,69:522-525.
  • 6Daniel P,Fowler AJ.Breathing system filter use for infectioncontrol and humidification during anesthesia and mechanicalventilation-a review[J].Middle East J Anesthesiol,2001.16:161-184.
  • 7Wilkes AR.Measuring the filtration performance ofbreathing system filters using Sodium chloride particles[J],Anaesthesia,2002.57:162-168.
  • 8Chiumello D,Pelosi P.Park G,et al.In vitro and in vivoevaluation of a new active heat moisture exchanger[J].CritCare,2004,8:R281-R288.
  • 9Iotti GA,Olivei MG,Braschi A.Mechanical effects of heat-moisture exchangers in ventilated patients[J].Crit Care.1999,3:R77-R82.
  • 10李璐,赵砚丽,牛巍巍.呼吸过滤器在长期人工通气中对细菌的过滤作用[J].临床荟萃,2008,23(6):407-409. 被引量:3

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部