摘要 目的:探讨基层医院运用肾活检术的临床意义,并对其安全性进行评估。方法:在B超引导下用BARDMAGNUM自动穿刺枪对52例肾脏病患者做肾活检术,将临床诊断与病理诊断作比较分析。结果:采用BARDMAGNUM自动穿刺枪的穿刺成功率为93.7%,术前临床误诊率为10.7%,术前诊断不明率为46.2%,术后全部病理确诊,术后治疗方案有较大修改的占23.1%。结论:采用BARDMAGNUM自动穿刺枪经皮超声引导肾活检术并发症少,风险小,在基层医院开展具有可行性;肾活检术的开展可明确诊断肾脏疾病,正确指导治疗及准确估计预后。 objective:to study the renal biopsy in basic-level hospitals use clinical significance,and the safety evaluation of progressive.Methods:B ultrasound guidance with BARD MAGNUM automatic biopsy gun to 52 cases with kidney patient do renal biopsy,clinical diagnosis and pathological diagnosis will make the comparative analysis.Results:the BARD MAGNUM automatic biopsy gun puncture the success rate 93.7%,preoperative clinical the misdiagnosis rate was 10.7%,the preoperative diagnosis of unknown 46.2%,postoperative pathological diagnosis all,postoperative treatment scheme has higher modified with 23.1%.Conclusion:the BARD MAGNUM automatic biopsy gun percutaneous ultrasound guidance kidney biopsy less complications,the risk is small,in the hospital has feasibility;The development of renal biopsy can be had a clear diagnosis,treatment and accurate estimate right direction prognosis.
作者 罗志远 陈果
机构地区 泸州市人民医院
出处 《求医问药(下半月刊)》 2012年第5期297-298,共2页 Seek Medical and Ask The Medicine
关键词 超声引导 肾活检术 病理诊断 穿刺 并发症 Ultrasound guided renal biopsy pathological diagnosis puncture complications
  • 相关文献

参考文献3

二级参考文献16

  • 1张武,吕国荣,贾建文,冉维强,苗立英,史旭东,黄曼维,赵蕊,丁丽华,冯麟增,李志平.超声引导自动组织学活检术临床应用[J].中华超声影像学杂志,1993,2(1):38-41. 被引量:27
  • 2谌贻璞,俞雁平.经皮肾穿刺活检并发症1000例分析[J].中华内科杂志,1993,32(6):392-395. 被引量:48
  • 3赵铖,孙安远,李智贤.利用活检枪在B超引导下肾活检75例临床分析[J].中国实用内科杂志,1997,17(1):32-33. 被引量:10
  • 4邹万患 等.肾脏病理与临床[M].长沙:湖南科学技术出版社,1993.3.
  • 5[1]Christensen J, Lindequist S,Knudsen DU,et al. Ultrasound-guided renal biopsy with biopsy gun technique-efficacy and complication. Acta Radio, 1995; 36:276-279
  • 6[2]Nyman R.S, Cappelen-Smith J,Suhaibani HA,et al. Yield and complications in percutaneous renal biopsy.Acta Radio,1997;38:431-436
  • 7[4]Anthony J, Martin C,Dariel A. Percutaneous native renal biopsy: Comparison of a 1.2-mm spring-driven system with a traditional 2-mm hand-driven system. AM J Kidney Dis,1994;23:498-503
  • 8[5]Diaz-Buxo JA,Donadio JA. Complications of percutaneous renal biopsy:an analysis of 1,000 consecutive biopsies. Clin Nephrol, 1975; 4:223-227
  • 9[6]Parrish AE. Complications of renal biopsy:a review of 37 years' experience.Clin Nephrol,1992;38:135-141