期刊文献+

The Effect of Non-Contact Conditions in a Splinted Fixed Partial Denture on the Load Sharing Mechanism: A Finite Element Study 被引量:3

The Effect of Non-Contact Conditions in a Splinted Fixed Partial Denture on the Load Sharing Mechanism: A Finite Element Study
原文传递
导出
摘要 A computer-aided design model for a fixed partial denture was constructed and used in a finite element analysis to study the overall load sharing mechanism between the fixed partial denture and oral structures while the denture base rested on the al- veolar ridge. To investigate the consequences of non-contact conditions, three additional models were generated incorporating a uniform clearance of 0.125 mm, 0.25 mm, and 0.5 mm, respectively. A 100 N static load located at the free end of the prosthesis was applied while the distal portion of the jaw was set fixed. The results show that whilst releasing the ridge almost entirely, the presence of the clearance drastically increased the load on the splinting teeth. A pull-out force on the canine tooth of about 44 N was computed, accompanied by a mesio-distal moment of about 500 N.cm. The combination of which was similar to the tooth extraction maneuver performed by the dentist. In contrast, the second premolar was found to bear a push-in force of almost 115 N. The first molar, though barely solicited in the contact condition, became substantially loaded in non-contact conditions, which validates the choice of sacrificing three teeth to support the denture. A computer-aided design model for a fixed partial denture was constructed and used in a finite element analysis to study the overall load sharing mechanism between the fixed partial denture and oral structures while the denture base rested on the al- veolar ridge. To investigate the consequences of non-contact conditions, three additional models were generated incorporating a uniform clearance of 0.125 mm, 0.25 mm, and 0.5 mm, respectively. A 100 N static load located at the free end of the prosthesis was applied while the distal portion of the jaw was set fixed. The results show that whilst releasing the ridge almost entirely, the presence of the clearance drastically increased the load on the splinting teeth. A pull-out force on the canine tooth of about 44 N was computed, accompanied by a mesio-distal moment of about 500 N.cm. The combination of which was similar to the tooth extraction maneuver performed by the dentist. In contrast, the second premolar was found to bear a push-in force of almost 115 N. The first molar, though barely solicited in the contact condition, became substantially loaded in non-contact conditions, which validates the choice of sacrificing three teeth to support the denture.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2012年第3期336-342,共7页 仿生工程学报(英文版)
关键词 finite element analysis splinted fixed partial denture hygienic space load transfer mechanism contact problem finite element analysis, splinted fixed partial denture, hygienic space, load transfer mechanism, contact problem
  • 相关文献

参考文献28

  • 1Wostmann B, Budtz-Jorgensen E, Jepson N, Mushimoto E, Palmquist S, Sofou A, Owall B. Indications for removable partial dentures: A literature review. International Journal of Prosthodontics, 2005, 18, 139-145.
  • 2McGivney G P, Castleberry D. MeCracken's Removable Partial Prosthodontics, 9th ed, The CV Mosby Company, St Louis, USA, 1995.
  • 3Mijiritsky E, Karas S. Removable partial denture design involving teeth and implants as an altemative to unsuc- cessful fixed implant therapy: A case report. Implant Den- tistry, 2004, 13,218-222.
  • 4Block M S, Kent J N. Prospective review of integral im- plants. Dental Clinics of North America, 1992, 36, 27-37.
  • 5E1-Wakad M T, Bendjaballah M Z. Finite element study of Load transfer in a splinted fixed partial denture. Egyptian Dental Journal, 2010, 56, 375-381.
  • 6Lin C L, Wang J C, Chang W J. Biomeehanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: A finite element analysis. Clinical Oral Implants Research, 2008, 19, 107-117.
  • 7E1-Wakad M T. Effect of splinting in a fixed partial denture on bone response: FEM study. Egyptian Dental Journal, 2009, 55, 1999-2005.
  • 8E1 Charkawi H G, E1-Wakad M T. Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro. Journal of Prosthetic Dentistry, 1996, 63, 315-320.
  • 9Menicucci G, Ceruti P, Barabino E, Screti A, Bignardi C, Preti G. A preliminary in vivo trial of load transfer in man- dibular implant-retained overdentures anchored in two dif- ferent ways, allowing and counteracting free rotation. In- ternational Journal of Prosthodonties, 2006, 19, 574-576.
  • 10Sadowsky S J, Caputo AA. Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. Journal of Prosthetic Den- tistry, 2000, 84, 327-334.