期刊文献+

CT低剂量技术新进展 被引量:11

Latest development of low-dose CT technique
下载PDF
导出
摘要 目的:探讨目前CT低剂量技术的最新进展。方法:从宽探测器的应用、探测器材质的更新换代、大pitch加快扫描速度及迭代重建算法的演变4个角度,阐述低剂量技术的原理、优缺点和发展趋势。结果:CT低剂量技术的应用,可以在保证诊断有效信息的前提下,降低患者辐射剂量最多可达86%。结论:尽管存在一些限制,先进的CT低剂量技术可以大大降低患者辐射剂量,并为更深广的诊断需求提供了可能。 Objective: To decrease the radiation for computed tomography examination and to improve the safety of patients is an important direction of the development of CT technique. Methods: We demonstrated the principles, merits and drawback and their potentialities of each kind of new low-dose CT technique. Results: With the new developed low-dose CT technique, patients' dose could be reduced by 86% without losing clinical information. Conclusion: Despite of some limitation, new developed low-dose CT techniques can decrease patients' dose dramatically and make more widely and deeply clinical needs possible.
出处 《中国医学装备》 2012年第8期48-52,共5页 China Medical Equipment
基金 国家自然科学基金(30870751)"多拍螺旋CT临床成像质量与受检者受照剂量优化配比及评价方法研究"
关键词 计算机断层成像 辐射剂量 受照剂量 Computed tomography Radiation dose Exposure dose
  • 相关文献

参考文献23

  • 1Hsiao EM, Rybicki F J, Steigner M. CT coronary angiography: 256-slice and 320-detector row scanners[J].Curr Cardiol Rep,2010, 12(1):68-75.
  • 2Choi SI, George RT, Schuleri KH, et al. Recent developments in wide-detector cardiac computed tomography[J].Int J Cardiovasc Imaging, 2009,25(Suppl 1): 23-29.
  • 3Perisinakis K, Damilakis J, Tzedakis A, et al. Determination of the weighted CT dose index in modem multi-detector CT scanners[J].Phys Med Biol, 2007.52(21): 6485-6495.
  • 4Khan A, Khosa F, Nasir K, et al. Comparison of radiation dose and image quality:320-MDCT versus 64-MDCT coronary angiography[J].AJR Am J Roentgenol, 2011,197(1): 163-168.
  • 5Perisinakis K, Papadakis AE, Damilakis J.The effect of x-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging[J].Med Phys, 2009,36(4) : 1258-1266.
  • 6Mori S, Nishizawa K, Kondo C, et al. Effective doses in subjects undergoing computed tomography cardiac imaging with the 256-muItislice CT scanner[J].Eur J Radiol. 2008.65(31: 442-448.
  • 7Scharf M, Bink R, May MS, et al. High- pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy[J].JACC Cardiovasc Imaging, 2011,4(6) : 602-609.
  • 8Hurlock GS, Higashino H, Mochizuki T. History of cardiac computed tomography: single to 320 detector row multislice computed tomography[J].Int J Cardiovasc Imaging, 2009,25(Suppl 1 ) .. 31-42.
  • 9Chen LK, Wu TH, Yang CC, et al. Radiation dose to patients and image quality evaluation from coronary 256-slice computed tomographic angiography[J].Nucl Med Commun,2010,619(1-3): 368-371.
  • 10Hausleiter J, Meyer T, Hadamitzky M, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates[J]. Circulation, 2006,113(10): 1305-1310.

同被引文献108

引证文献11

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部