摘要 目的应用三维数字减影血管造影(Digital subtraction angiography,DSA),对颅内动脉瘤进行诊断,详细了解颅内动脉瘤的解剖特征及血流动力学的改变,通过对数字平板探测器DSA的各种常用成像模式的对比分析,旨在合理有效的使用数字平板探测器DSA的各种成像模式对颅内动脉瘤进行精确诊断和评估。方法研究包含32例患者(38个动脉瘤),均为已经破裂过的动脉瘤,均进行过数字平板探测器DSA的检查,由两名具有高级职称的神经放射学家独立对3D-DA的各种常用模式图像和旋转DSA的图像进行评估。四分法系统被用来对动脉瘤进行诊断和术前评估,对比分析各种成像模式对动脉瘤的诊断和细节显示。结果对于被证实的38个动脉瘤的诊断,常规2D-DSA图像明显不如旋转DSA图像和3D-DA图像。对于动脉瘤的细节显示,旋转DSA图像明显不如3D-DA图像的各种常用模式,而3D-DA图像的各种常用模式之间基本没有显著性差异。结论对于颅内动脉瘤的术前评估,3D-DA图像比旋转DSA图像和2D-DSA图像能提供更多有用的信息。 Objective To use 3D digital tablet detector DSA,carries on the diagnosis of intracranial aneurysms, detailed understanding the anatomical characters of intracranial aneurysms, through of digital tablet detector DSA, comparison and analysis of the common imaging approach aimed at reasonable and effective use of digital tablet detector DSA of imaging mode intracranial aneurysm on preoperative diagnosis and evaluation. Methods Prospectie study contains 32 patients (38 aneurysm), is all the aneurysm is broken, underwent digital fiat detector DSA check, by two neuroradiologists independence evaluated for 3D-DA various kinds of image and rotation DSA mode of image. Four points law system is used to diagnosis and preoperative assessment aneurysm, c0ontrast analysis of various imaging mode on the diagnosis and detail shows for aneurysm. Results To be confirmed the detectiong of the 38 aneurysm, conventional 2D-DSA image obviously lower than rotating DSA image and 3D-DA image. For the delineation of the aneurysm, rotate DSA image obvious lower than 3D-DA image all kinds of common mode, and the image of various kinds 3D-DA between basically no significant difference. Conclusion For the preoperative assessment intracranial aneurysms, 3D-DA image than rotation DSA image and 2D-DSA image can provide more useful information.
出处 《当代医学》 2012年第24期104-106,共3页 Contemporary Medicine
关键词 3D-DA 常用模式 颅内动脉瘤 诊断 术前评估 3D-DA Common mode Intracranial Aneurysms Diagnosis Pretreatment Evaluation
  • 相关文献

参考文献5

  • 1Toshinori hiral,Yukonori korogic,Kenji Suginohara.Clinical Usefulness of Unsubtracted 3D Digital Angiography Compared with Rotational Digital Angiography in the Pretreatment Evaluation of Intracranial Aneurysms[J].AJNR,2003,24:1067-1074.
  • 2Fleiss JL.Statistical Methods for Rates and Proportions[M].2nd ed.New York:Wiley,1981:212.
  • 3Anxionnat R,Bracard S,Ducrocq X,et al.Intracranial aneurysms:clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment[J].Radiology 2001,218:799-808.
  • 4Missler U,Hundt C,Wiesmann M,et al.Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms[J].Eur Radiol 2000,10:564-568.
  • 5赵卫,苟礼云,王涛,陈锦州.3D平板探测器在颅内动脉瘤栓塞治疗中测量误差的分析[J].当代医学,2010,16(35):757-760. 被引量:1

二级参考文献3

  • 1M.Piotin,B.Daghman,C.Mounayer et al Ellipsoid Approximation versus 3D Rotational Angiography in the Volumetric Assessment of Intracranial Aneurysm.American Journal of Neuroradiology 27:839-842,April 2006.
  • 2Javier OlivánBesc ós,Marjan J.SIob,Cornelis H.Slump et al Volume Measurement of Intracranial Aneurysms from 3D Rotational Angiography:lmprovernertt of Accuracy by Gradient Edge Detection.American Journal of Neuroradiology 26:2569-2572,November-December 2005.
  • 3张泽宝,吉强,等主编.《医学影像物理学》2版.2006年6月1日,人民卫生出版社.