摘要
A novel biopolymer/room-temperature ionic liquid composite film based on carrageenan, room temperature ionic liquid (IL) [1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4)] was explored for immobilization of hemoglobin (Hb) and construction of biosensor. Direct electrochemistry and electrocatalytic behaviors of Hb entrapped in the IL-carrageenan composite film on the surface of glassy carbon electrode (GCE) were investigated. UV-vis spectroscopy demonstrated that Hb in the IL-carrageenan composite film could retain its native secondary structure. A pair of well-defined redox peaks of Hb was obtained at the Hb-IL-carrageenan composite film modified electrode through direct electron transfer between the protein and the underlying electrode. The heterogeneous electron transfer rate constant (ks) was 2.02 s 1, indicating great facilitation of the electron transfer between Hb and IL-carrageenan composite film modified electrode. The modified electrode showed excellent electrocatalytic activity toward reduction of hydrogen peroxide with a linear range of 5.0 × 10-6 to 1.5 ×10-4 mol/L and the detection limit was 2.12 ×10 7 mol/L (S/N= 3). The apparent Michaelis-Menten constant KM^app for hydrogen peroxide was estimated to be 0.02 mmol/L, indicating that the biosensor possessed high affinity to hydrogen peroxide. In addition, the proposed biosensor showed good reproducibility and stability.
A novel biopolymer/room-temperature ionic liquid composite film based on carrageenan, room temperature ionic liquid (IL) [1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4)] was explored for immobilization of hemoglobin (Hb) and construction of biosensor. Direct electrochemistry and electrocatalytic behaviors of Hb entrapped in the IL-carrageenan composite film on the surface of glassy carbon electrode (GCE) were investigated. UV-vis spectroscopy demonstrated that Hb in the IL-carrageenan composite film could retain its native secondary structure. A pair of well-defined redox peaks of Hb was obtained at the Hb-IL-carrageenan composite film modified electrode through direct electron transfer between the protein and the underlying electrode. The heterogeneous electron transfer rate constant (ks) was 2.02 s 1, indicating great facilitation of the electron transfer between Hb and IL-carrageenan composite film modified electrode. The modified electrode showed excellent electrocatalytic activity toward reduction of hydrogen peroxide with a linear range of 5.0 × 10-6 to 1.5 ×10-4 mol/L and the detection limit was 2.12 ×10 7 mol/L (S/N= 3). The apparent Michaelis-Menten constant KM^app for hydrogen peroxide was estimated to be 0.02 mmol/L, indicating that the biosensor possessed high affinity to hydrogen peroxide. In addition, the proposed biosensor showed good reproducibility and stability.