期刊文献+

Experimental Study on Mechanical Behavior of Box-Brace to Box-Column Foot Joints

Experimental Study on Mechanical Behavior of Box-Brace to Box-Column Foot Joints
原文传递
导出
摘要 This paper presents results of three tests carried out to study the mechanical behavior of foot joints used in the tower boiler steel frame. Each foot joint consists of a box column and a box brace. These three specimens have different connection types or different details of stiffeners. The tests are carried out by using the large multi-function structural experiment system WAW-1000J. The load-displacement curves and the strain distribution are measured during the tests. The mechanical behavior of foot joints under adverse load cases is analyzed. The safety of these three specimens under design load is assessed. The strength and deformation of different joints are compared. The results indicate that connection types or details of inner stiffeners have effects on strength and failure mode and that the specimen with end-plate connection can optimize the strain distribution along the height of brace web and can change the force transfer mechanism between column and brace. In addition, a finite element model of the specimen is conducted and numerical results generally agree well with the test results. The work in this paper provides a base for further analysis on the performance of joint used in the tower boiler steel frames. This paper presents results of three tests carried out to study the mechanical behavior of foot joints used in the tower boiler steel frame. Each foot joint consists of a box column and a box brace. These three specimens have different connection types or different details of stiffeners. The tests are carried out by using the large multi-function structural experiment system WAW-1000J. The load-displacement curves and the strain distribution are measured during the tests. The mechanical behavior of foot joints under adverse load cases is analyzed. The safety of these three specimens under design load is assessed. The strength and deformation of different joints are compared. The results indicate that connection types or details of inner stiffeners have effects on strength and failure mode and that the specimen with end-plate connection can optimize the strain distribution along the height of brace web and can change the force transfer mechanism between column and brace. In addition, a finite element model of the specimen is conducted and numerical results generally agree well with the test results. The work in this paper provides a base for further analysis on the performance of joint used in the tower boiler steel frames.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2012年第4期385-390,共6页 上海交通大学学报(英文版)
基金 the Key Scientific and Technological Project Supported by the Science and Technology Commission of Shanghai Municipality (No.072012028)
关键词 foot joint tower boiler strength connection STIFFENER foot joint, tower boiler, strength, connection, stiffener
  • 相关文献

参考文献13

  • 1SATISH KUMAR S R, PRASADA RAO D V. RHS beam- to-colunm connection with web opening: Experimen- tal study and finite element modelling [J]. Journal of Construtetional Steel Research, 2006, 62(8): 739-746.
  • 2SHANMUGAM N E, RICHARD LIEW J Y, LEE S L. Ultimate strength design of biaxially loaded steel box beam-columns [J]. Journal of Constructional Steel Research, 1993, 26(2-3): 99-123.
  • 3ZHAO X L, HANCOCK G J. Square and rectangular hollow sections under transverse end-bearing force [J]. Journal of Structural Engineering, 1995, 121(9): 1323- 1329.
  • 4Yoo C H, CHOI B H, FORD E M. Stiffness require- ments for longitudinally stiffened box-girder flanges [J]. Journal of Structural Engineering, 2001, 127(6): 705-711.
  • 5K1M K, Yoo C H. Ultimate strengths of steel rect- angular box beams subjected to combined action of bending and torsion [J]. Engineering St'ructures, 2010, 30(6): 1677-1687.
  • 6GRoss J L. A connection model for the seismic anal- ysis of welded steel moment frames [J]. Engineerin9 Structures, 1998, 20(4): 390-397.
  • 7SHI G, SHI Y J, WANG Y Q. Behaviour of end-plate moment connections under earthquake loading [J]. En- gineering Structures, 2007, 29(5): 703-716.
  • 8SHANMUGAM N E, TING L C, LEE S L. Non-linear analysis of I-beam to box-column connections [J]. Journal of Constructional Steel Research, 1994, 28(3): 257-278.
  • 9SHANMUGAM N E, TING L C. Welded interior box- column to I-beam connections [J]. Journal of Struc- tural Engineering, 1995, 121(5): 824-830.
  • 10CHEN C, LIN C, TSAI C. Evaluation of reinforced con- nections between steel beams and box columns [J]. En- gineering Structures, 2004, 26(13): 1889-1904.