摘要 纤维塑料(FRP)连接件是连接预制混凝土夹芯保温墙体内外层混凝土墙板的关键部件,在墙体中主要承受拔出荷载与剪切荷载。以北京某住宅工程为背景,对板式FRP连接件的材料性能进行了测定,并对此种连接件的抗拔及抗剪性能进行了试验研究。研究表明:连接件抗拔承载力为11.2 kN,抗剪承载力为15.3 kN,满足工程设计要求,并具有较大的安全储备。 Fiber reinforced plastic (FRP) connectors which tied internal and external concrete wall- board together were important parts which mainly exposed to the pull out load and shear load in precast con- crete sandwich wall panels. Take residential project in Beijing as the example, the FRP connectors'material properties indicators were investigated, anti-pulling behavior and shear behavior of plate FRP connectors were tested. The resuhs showed that pull-out 11.2 kN and 15.3 kN respectively. The safety margin as well. bearing capacity and shear bearing capacity of the connector were connector could meet the requirements of the design, and had great safety margin as well.
出处 《塑料工业》 CAS CSCD 北大核心 2012年第8期69-72,共4页 China Plastics Industry
基金 上海市科委项目(10dz1202200 10dz0583700)
关键词 纤维塑料连接件 抗拔承载力 抗剪承载力 FRP Connector Pull-out Bearing Capacity Shear Bearing Capacity
  • 相关文献

参考文献8

  • 1U. S. A-Japan cooperative research program committee. Ten- sile tests of lap-spliced joint for precast concrete panel con- nections Part 2 - 1 [ M ]. Gaithersburg : NIST Special Publi- cation, 1991.
  • 2ICC Evaluation committee. ICC-ES AC320. Acceptance cri- teria for fiber-reinforced composite connectors anchored in concrete [S]. Washington DC: A Subsidiary of the interna- tional code council, 2009.
  • 3Al-EINA. State of the art of precast concrete sandwich panels [J]. PCIJ, 1991, 36 (6): 78-98.
  • 4WADE G T, PORTER M L, JACOBS D R. Glass-fiber composite connectors for insulated concrete sandwich walls [R]. Iowa: Iowa State University, 1988.
  • 5RAMM W. Report concerning shear tests under static load with regard to three-layered fa ade panels with an anchoring according to the thermomass building system ( in German ) [R]. Kaiserslautern: University of Kaiserslautern, 1991.
  • 6RAMM W. Report concerning stress and shear tests with stat- ic load concerning anchoring of three--layered fa ade panels according to the Thermomass building system [ R]. Kaisers- lautern : University of Kaiserslautern, 1992.
  • 7PORTER M L, BARNES B A. An elemental test series on low-cycle fatigue behavior of ties subjected to cold tempera- tures and in-plane shear [ R ]. Iowa: Iowa State University, 1991.
  • 8PCI Committee Report. State-of-the-art of precast/prestressed sandwich wall panels [J]. PCI J, 1997, 42 (2): 92 - 134.