摘要
建立了油辣椒中罗丹明B的高效液相色谱-串联四极杆质谱联用测定方法,该方法经乙腈提取样品,以waters-C18柱(2.1×50mm,1.7μm)分离,流动相为甲醇-0.1%甲酸水,电喷雾正离子MRM模式检测。方法检出限0.1ng/mL,线性范围0.1μg/L~10μg/L,加标回收率99.5%~106.4%,相对标准偏差为1.08~3.07%。
This thesis developed a LC -MS -MS method for rhodamine B in oil chili. The mass spectrometer was operated in the positive ion mode using multiple reaction monitoring. In the method, A sample was extracted with acetonitrile, Chromatographic separation was carried out on a Waters -C18 column (2.1 ×50 mm, 1.7 μm)using methyl alcohol and water ( containing 0.01% (v/v) formic acid ). The limit of detection is 0. lng/mL, the linear plots were 0.05 μg/L - 10 μg/L. Overall recoveries were 99.5% - 106.4%, and RSD value was 1.08%- 3.07%.
出处
《贵州化工》
2012年第4期30-32,共3页
Guizhou Chemical Industry