摘要
针对当前数据中心节能整合研究中仅考虑服务器能耗的现状,提出一种同时考虑服务器和网络设备能耗的方法。该方法通过感知数据中心的网络拓扑,使运行的服务器和网络设备最少,以此最小化能耗。对问题进行新的形式化建模,并设计一种混合的粒子群优化算法HPSO-NA来实现虚拟机整合。实验结果表明,该方法能有效降低整体能耗。
Since current researches on energy efficient consolation in data center only consider part of energy consumed by servers,this paper proposes a novel method considering both servers and network devices.The proposal achieves energy minimization by minimizing the active servers and network devices through analyzing the net topology.Moreover,the problem is modeled and a hybrid particle swarm algorithm called HPSO-NA is designed to implement virtual machine consolidation.Experimental results show that the proposed method can effectively reduce the energy consumption.
出处
《计算机工程》
CAS
CSCD
2012年第15期276-278,282,共4页
Computer Engineering
基金
国家"863"计划基金资助重大专项(2008AA04A107)
国家科技支撑计划基金资助项目(2009BAH46B0302)
关键词
能耗最小
网络感知
整合
虚拟机迁移
粒子群优化
装箱问题
energy consumption minimization
network awareness
consolidation
virtual machine migration
particle swarm optimization
bin-packing problem