期刊文献+

300MW等级机组加装低压省煤器系统节能分析 被引量:2

Analysis on energy-saving effect of low-pressure economizer installed in 300 MW grade units
下载PDF
导出
摘要 电厂加装低压省煤器系统后,节能效益一直存在争议,以某电厂300 MW等级机组加装低压省煤器系统改造为例,将理论节能计算结果与现场测试结果进行对比分析,客观分析了低压省煤器系统在300 MW等级机组应用的节能效果。 Aiming at the question of the energy-saving benefit of the low-pressure economizer installed in power generation unit,taking a system reformation project of a power plant,in which the low-pressure economizer was installed in a 300 MW grade unit,as example,the energy-saving effect obtained by theoretical calculation was compared with the site measured result,and the energy-saving effect of the low-pressure economizer applied in 300MW grade unit was analyzed objectively.
作者 石岩 梁秀进
出处 《华电技术》 CAS 2012年第8期73-76,80,共4页 HUADIAN TECHNOLOGY
关键词 低压省煤器 排烟温度 节能 low-pressure economizer outlet gas temperature energy-saving