表面等离子体共振技术对过氧化氢的检测 被引量:2

Surface Plasmon Resonance Detection of Hydrogen Peroxide
下载PDF
导出
摘要 表面等离子体激元共振技术是一种通过观察芯片金属薄膜表面厚度变化产生信号的光学技术,具有实时、灵敏度高、免标记等优点,本文通过辣根过氧化物酶的酶催化作用对过氧化氢进行实时快速检测。信号强度与过氧化氢浓度呈线性关系,辣根过氧化物酶共价结合至金膜表面保持了酶的活性。和其它方法相比较,该方法为过氧化氢的检测提供了一种选择。 Surface plasmon resonance(SPR) was an optical technique that measured the changes occuring at the metal film interface.It can detect samples in a real-time,highly sensitive,and label-free way.Based on horseradish peroxidase(HRP)-biocatalyzed oxidation,SPR was utilized to detect H2O2.The SPR dip shift increased linearly with the concentration of hydrogen peroxide.The convalent binding of HRP on the Au film retained the catalytic activity of HRP.In comparsion with other techniques,the sensing protocol provided an alternative for hydrogen peroxide detection.
作者 开天瀚
出处 《广州化工》 CAS 2012年第15期145-147,共3页 GuangZhou Chemical Industry
关键词 表面等离子体共振 过氧化氢 辣根过氧化物酶 surface plasmon resonance hydrogen peroxide horseradish peroxidase
  • 相关文献

参考文献10

  • 1Anglada, J. M. , P. Aplincourt, J.M. Bofill, et al. Atmospheric formation of OH radicals and H2O2 from alkene ozonolysis under humid conditions [ J ]. ChemPhysChem ,2002,3 (2) :215 - 221.
  • 2Ohshima, H. , M. Tatemichi, T. Sawa. Chemical basis of inflammation - induced carcinogenesis[ J ]. Archives of biochemistry and biophysics, 2003,417(1) :3 - 11.
  • 3Shah, A. , K. Channon. Free radicals and redox signalling in cardiovascular disease [ J ]. Heart,2004,90 (5) :486 - 487.
  • 4Barnham, K.J. , C.L. Masters, A.I. Bush. Neurodegenerative diseases and oxidative stress [ J ]. Nature Reviews Drug Discovery, 2004,3 (3) :205 -214.
  • 5Wood, Z. A. , L.B. Poole, P.A. Karplus. Peroxiredoxin evolution and the regulation of hydrogen peroxide signaling [ J ]. Science's STKE, 2003,300(5619) :650.
  • 6Wu, M. , Z. Lin, M. Schaferling, et al. Fluorescence imaging of the activity of glucose oxidase using a hydrogen - peroxide - sensitive europium probe [ J ]. Analytical biochemistry,2005, 340 ( 1 ) : 66 - 73.
  • 7Chai, X.S. , Q. Hou, Q. Luo, et al. Rapid determination of hydrogen peroxide in the wood pulp bleaching streams by a dual - wavelength spectroscopic method [ J ]. Analytica chimica acta,2004,507 ( 2 ) : 281 - 284.
  • 8Wei, H. , E. Wang. Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection [ J ]. Analytical chemistry,2008,80 (6) : 2250 - 2254.
  • 9Wolfbeis, O. S. , A. Durkop, M. Wu, et al. A Europium - Ion - Based Luminescent Sensing Probe for Hydrogen Peroxide [ J ]. Angewandte Chemie International Edition,2002,41 (23) :4495 - 4498.
  • 10Thiagarajan, S. , T. H, Tsai, S.M. Chen. Electrochemical Fabrication of Nano Manganese Oxide Modified Electrode for the Detection of H2O2 [J].Int. J. Eleetrochem. Sci,2011(6):2235-2245.

同被引文献45

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部