期刊文献+

采用折流杆技术对传统低加芯改造

Transformation of traditional low and core used the baffle pole technique
下载PDF
导出
摘要 对200 MW发电机组低加铜管容易断裂泄漏进行分析,采用新型折流杆技术对低加芯进行改造,就用原来壳体,换热管可选用钢管或不锈钢管代替铜管。改造后的折流流杆低加具有换热效率高、防振性强、不易结垢、使用寿命长等优点,具有重要应用价值。 Reasons of the low pressure heater copper pipe’s broken and leakage of a type of 200 MW power generator is analysised,a new the baffle pole technology is adopted in the low pressure heater of brass tube alteration,the low pressure heater of tubes are optional steel tube or stainless steel tube in place of copper tube.Application results show that the reformed low pressure heater has advantages of improved transmission efficiency with simple system structure,better performance of anti-vibration and encrustation capability.This technology has very important application value.
作者 吕圣杰
出处 《大众科技》 2012年第8期120-121,共2页 Popular Science & Technology
关键词 折流杆低加 折流板低加 铜管 钢管 断裂 泄漏 换热效率 baffle pole low pressure heater baffle plate low pressure heater copper pipe steel pipe rupture leakage efficient of heat exchanger
  • 相关文献

参考文献7

  • 1兰州石油机械研究所主编.换热器(上册)[M].中国 石化出版.
  • 2兰州石油机械研究所主编.换热器(下册)[M].中国 石化出版.
  • 3兰州石油机械研究所主编.换热器(中册)[M].中国 石化出版.
  • 4中华人民共和国国家标准.GB151-1999,管壳式换热器[S]. 北京:中国标准出版社.
  • 5邢华伟,新型换热设备一折流杆换热性能研究[D].武汉:华 中理工大学硕士学位论文.
  • 6中华人民共和国电力行业标准.火电发电厂设计技术规程 [S].中国电力出版社出版.
  • 7广东省电力试验研究所.韶关发电厂#8汽轮机组表面式 加热器性能试验报告[R].

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部