摘要
针对某具体工程中加气混凝土砌块墙面抹灰后出现的空鼓,裂缝情况进行了分析,阐述了产生病变的原因,从材料、施工工艺及养护等方面入手,提出了防治措施,并指出了墙体抹灰控制要点,以指导今后同类墙面抹灰施工。
The paper analyzes the empty drum and the cracks on the aerated concrete blockwork surface after the plastering,illustrates the reasons for the lesion,points out the prevention measures from the materials,the construction craft and the maintenance,and indicates the controlling points for the wall plastering,so as to direct the plastering construction on similar walls in future.
出处
《山西建筑》
2012年第25期248-248,256,共2页
Shanxi Architecture
关键词
加气混凝土砌块墙面
抹灰
质量控制
aerated concrete blockwork surface
plastering
quality control