摘要
Radio frequency(RF) measurement has become a hot issue for partial discharge detection.However,its application is hampered by the difficulty to establish a relationship between the RF measurements data and apparent discharge quantity.In this paper,on the basis of an experimental model of metal protrusion,the relationship between the results of RF measurement and pulse current method(IEC 60270) was investigated.The energy,double integration,peak voltage,peak-peak voltage and the area of RF signals were plotted versus either the apparent discharge quantity or the square of the apparent discharge quantity in order to evaluate the optimal regression curve.At the same time,the impact of voltage and the distance between protrusion and plate were also investigated.The results indicate that the optimal match to a linear regression curve can be gained by plotting the RF signal energy versus the square of the apparent discharge quantity.The variation of voltage has no significant impact on the regression curve;that is,data from different voltages match one line.However,when the distance between protrusion and plate is changed,the slope of the regression curve changes accordingly;the same energy corresponds to a bigger discharge quantity.The results are significant enough to be applied in the estimation of the discharge quantity by measuring RF partial discharge signals.
Radio frequency(RF) measurement has become a hot issue for partial discharge detection.However,its application is hampered by the difficulty to establish a relationship between the RF measurements data and apparent discharge quantity.In this paper,on the basis of an experimental model of metal protrusion,the relationship between the results of RF measurement and pulse current method(IEC 60270) was investigated.The energy,double integration,peak voltage,peak-peak voltage and the area of RF signals were plotted versus either the apparent discharge quantity or the square of the apparent discharge quantity in order to evaluate the optimal regression curve.At the same time,the impact of voltage and the distance between protrusion and plate were also investigated.The results indicate that the optimal match to a linear regression curve can be gained by plotting the RF signal energy versus the square of the apparent discharge quantity.The variation of voltage has no significant impact on the regression curve;that is,data from different voltages match one line.However,when the distance between protrusion and plate is changed,the slope of the regression curve changes accordingly;the same energy corresponds to a bigger discharge quantity.The results are significant enough to be applied in the estimation of the discharge quantity by measuring RF partial discharge signals.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2012年第8期1828-1833,共6页
High Voltage Engineering
基金
supported by National Basic Research Program of China(973 Program)(2009CB724506)
National Natural Science Foundation of China(50977095)
关键词
局部放电
射频信号
放电量
高电压技术
radio frequency
partial discharge
discharge quantity
pulse current method
energy
linear regression curve