期刊文献+

单正激驱动变压器的磁通复位问题分析

Analysis on the Single Ended Forward Drive Transformer Flux Reset
原文传递
导出
摘要 本文对采用变压器隔离的单端正激式晶闸管驱动电路进行了分析研究,主要讨论了其传递宽脉冲触发存在的问题,采用高频调制脉冲列触发带来的优点,以及高频调制脉冲列触发所涉及的磁通复位、波形畸变及有关参数设计问题。磁通复位原理的分析,并不只局限在本文所研究内容中,对于开关电源设计也具有指导和借鉴意义。 In this paper, the single ended forward thyristor drive circuit with transformer isolation is analyzed and investigated. The paper mainly discusses the problems as wide trigger pulse transferred, the advantages using high frequency trigger modulation pulse sequence and related problems such as magnetic flux reset, waveform distortion and relevant parameter design involved in high frequency trigger modulation pulse sequence. The research on magnetic reset problem can provide good guidance and reference significance not only for the contents in this paper, but also for the switching mode power suply design.
作者 张超 徐向华
出处 《电源世界》 2012年第8期32-33,59,共3页 The World of Power Supply
关键词 单端正激式 高频调制脉冲 磁通复位 参数设计 Single ended forward, High frequency modulation pulse, Magnetic flux reset, Parameter design