摘要 在生产实践过程中,高压气淬炉一直以来存在着换热效率低下的问题。根据传热学基本原理,异形结构换热管可以提高换热效率。因此,为了进一步提高换热效率,对换热器设计工作包括3个部分:把换热光管改进为鳍片管,折流板由弓形改为螺旋型,并且把钢质换热材料替换为铜质以进一步提高换热效率。实践证明,与传统的换热设备相比,改进后的结构达到了强化传热的效果,有效地提高了换热设备的传热能力。 In the production practice process, there existed a problem of low heat transfer efficiency in high pressure gas quenching furnace. According to the basic principle of heat transfer, the heat transfer ef- ficiency would be improved by the heat exchange tub with especial - shaped structure. So in order to fur- ther improve the heat transfer efficiency, our heat exchanger design includes three parts. The heat ex- change tube was designed into a tube with a group of fins, bow baffle plate was replaced by the spiral ones and copper heat exchange material was instead of steel. It is found that the improved design has strength- ened the heat transfer effect and effectively improved the heat transfer ability of heat - exchange facility.
出处 《压力容器》 2012年第8期65-68,共4页 Pressure Vessel Technology
基金 天津市科技支撑重点项目(10ZCKFGX01600)
关键词 高压气淬炉 鳍片换热器 传热强化 高效节能 high - pressure gas quenching furnace fins heat exchanger heat transfer enhancement ener-gy efficient
  • 相关文献

参考文献10

二级参考文献66

共引文献88

同被引文献34

  • 1Tian Z, Love J A. Energy Performance Optimization of Radiant Slab Cooling Using Building Simulation and Field Measurements [ J ]. Energy and Buildings, 2009,41 (3) :320-330.
  • 2Wang S, Morimoto M. Evaluating the Iw Exergy of Chilled Water in a Radiant Cooling System [ J ]. Ener- gy and Buildings,2008,40(10) : 1856-1865.
  • 3Catalina T,Virgone J, Kuznik F. Evaluation of Thermal Comfort Using Combined CFD and Experimentation Study in a Test Room Equipped with a Cooling Ceiling [ J]. Building and Environment, 2009,44 ( 8 ) : 1740- 1750.
  • 4Feustel H E, Stetiu C. Hydranic radiant cooling -pre- liminary assessment [ J ]. Energy and Buildings, 1995, 22 (3) : 193-205.
  • 5Stetiu C. Energy and Peak Power Savings Potential of Radiant Cooling Systems in US Commercial Buildings [ J ]. Energy and Buildings, 1999,30 (2) : 127-138.
  • 6韩滔.基于动态热舒适的空调控制方案研究[D].成都:西南交通大学,2003.
  • 7ASHRAE. ASHRAE Handbook - Fundamentals [ S ]. Atlanta: American Society of Heating , Refrigerating and Air - Conditioning Engineers, Inc. , USA, 2001.
  • 8ISO Standard 7730. Moderate Thermal Environments -Determination of the PMV and PPD Indices and Specification of The Conditions for Thermal Comfort [ S ]. Switzerland: International Standard Organiza- tion, 2005.
  • 9Mumma S A, Lee B W. Extension of the Multiple Spaces Concept of ASHRAE Standard 62 to Include Infiltration, Exhaust/exfiltration, Interzonal transfer, and Additional Short Circuit Paths [ J ]. ASHRAE Trans,1998,104 (2) :1232-1241.
  • 10ASHRAE. ANS/ASHRAE Standard 55 - 2004. Ther- mal Environment Conditions for Human Occupancy [ S ]. Adanta : American Society of Heating, Refriger- ating and Air Conditioning Engineers Inc. ,2004.