摘要 目的研究不同聚合方法对义齿基托树脂吸水性和溶解性的影响。方法选择两种常用热凝义齿基托树脂材料,分别采用传统水浴法和电热聚合法制作样本,测量各样本的吸水值和溶解值。结果日进水浴组、日进电热组、贺利氏水浴组、贺利氏电热组的吸水值依次为(25.48±3.04)μg/mm3、(22.96±4.6)μg/mm3、(22.65±5.44)μg/mm3、(18.21±5.19)μg/mm3,以上各组的溶解值依次为(0.62±0.17)μg/mm3、(0.54±0.18)μg/mm3、(0.56±0.10)μg/mm3、(0.51±0.11)μg/mm3。日进水浴组的吸水值稍高,差别有统计学意义,其余各组比较均无差别。结论不同聚合方法对义齿基托树脂吸水性和溶解性并无显著影响,所制作样本均符合国家标准。 Objective To evaluate the influence of the polymerlization methods on water sorption and water solubility of the denture base polymers. Methods Two denture-base resins were selected, and the materials were prepared by traditional water-bath method or the electric-heating method. Evaluate the water sorption and water solubility of each kind of material. Results The water sorption of Nissin + water-bath, Nissin + electric-heating, Heraeus + water-bath, Heraeus + electric-heating were (25.48 ± 3.04) μg/mm^3 、( 22.96±4.6) μg/mm^3 、 (22.65 ±5.44) μg/mm^3 、( 18.21 ± 5.19) μg/mm^3. The water solubility of the four groups were (0.62± 0. 17 )μg/mm3、(0.54 ±0.18) μ g/mm^3 、 (0.56 ±0.10) μg/mms 、(0.51 ±0. 11 ) μg/mm^3. The water sorption of Nissin prepared by tradi- tional water-bath method was a little stronger, and the differences were significant ( P 〈 0.05 ). There was no difference in water sorp- tion and water solubility among the other groups. Conclusions There was no significant influence of the polymedization methods on the water sorption and water solubility of the denture base polymers. The water sorption and water solubility of all the materials fulfilled the Standards YY0270 - 2003.
出处 《口腔医学》 CAS 2012年第8期459-460,481,共3页 Stomatology
基金 杭州市科技局卫生专项项目(20100633B06)
关键词 基托聚合方法 电热聚合法 吸水性 溶解性 denture polymerlization methods electric-heating method water sorption water solubility
  • 相关文献

参考文献10

  • 1Wong DM, Cheng LY, Chow TW, et al. Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures[J]. J Prosthet Dent, 1999, 81(3) : 300 -304.
  • 2陈志清.口腔材料学[M].4版.北京:人民卫生出版社,2008:36.
  • 3Takahashi Y, Chai J, Kawaguchi M. Effect of water sorption on the resistance to plastic deformation of a denture base material re- lined with four different denture reline materials [ J ]. Int J Prosth- odont, 1998, (11) :49 -54.
  • 4Pfeiffer P, Rosenbauer EU. Residual methyl methacrylate mono- mer, water sorption, and water solubility of hypoallergenic denture base materials [J]. J Prosthet Dent, 2004, 92( 1 ) :72 -78.
  • 5Lassila LV, Vallittu PK. Denture base polymer alldent sinomer: mechanical properties, water sorption and release of residual com- pounds [J]. J Oral Rehabil, 2001,28(7) :607 -613.
  • 6Vallittu PK, Miettinen V, Alakuijala P. Residual monomer con- tent and its release into water from denture base materials [ J ]. Dent Mater, 1995, 11 (6) :338 -342.
  • 7Kurata S, Yamazaki N. Synthesis of dimethacryloxyethy 1 - 1,1, 6,6 - tetrahydro - perfluorohexa methylene - 1,6 - dicarbamate as dental base monomers and the mechanical properties of the co- polymers of the monomer and methyl methacrylate [J]. Dent Ma- ter J, 2011, 30(1) :103 -108.
  • 8Jorge JH, GiamPaoIo ET, Maehado AL, et al. Cytotoxicity of den- ture base aerylieresins: literature review [ J ]. J Prosthet Dent, 2003, 90(2) :190 - 193.
  • 9林映荷,邓红颖,巢永烈,李思毅,王波.微波加热法及常规水浴法处理聚甲基丙烯酸甲酯基托材料的性能比较研究[J].华西口腔医学杂志,1999,17(1):75-77. 被引量:9
  • 10蔡玉惠,周国兴,王国平.蒸汽压力机热处理义齿基托材料的实验性研究[J].口腔医学,2001,21(3):125-126. 被引量:2

二级参考文献7

  • 1高资彬 翁秀和(译).牙科材料学[M].中国台北:合记图书出版社,1977.34.
  • 2汪思谦.物理,第2版[M].上海:上海科学技术出版社,1983.277.
  • 3陈治清,口腔材料学,1993年,17页
  • 4陈治清,口腔材料学,1993年,52页
  • 5刘鸿文,材料力学(第3版),1992年
  • 6陈治清,最新口腔材料学,1989年,23页
  • 7方金素,张春宝,王宝成.不同出盒温度对义齿塑料基托适合性的影响[J].实用口腔医学杂志,1998,14(3):183-183. 被引量:5

共引文献10

同被引文献15

  • 1陈志清.口腔材料学[M].4版.北京:人民卫生出版社,2008:21-22.
  • 2Lee HH, Lee CJ, Asaoka K. Correlation in the mechanical prop- erties of acrylic denture base resins [ J ]. Dent Mater J, 2012,31 (1) :157 -164.
  • 3Zappini G, Kammann A, Wachter W. Comparison of fracture tests of denture base materials [ J ]. J Prosthet Dent,2003,90 ( 6 ) : 578 -585.
  • 4Pfeiffer P,Rolleke C,Sherif L. Flexural strength and moduli of hy- poallergenie denture base materials [ J ]. J Prosthet Dent,2005,93 (4) :372 - 377.
  • 5Machado C, Sanchez E, Azer SS, et al. Comparative study of the transverse strength of three denture base materials [ J]. J Dent, 2007,35(12) :930 -933 .
  • 6Bentaher HA, Juszezyk AS, Deb S, et al. Flexural strength and degree of polymerization of a proprietary denture base acrylic resin designed to be cured using long or short cycles [J]. Eur J Prosth- odont Restor Dent,2012,20(4) :163 - 167.
  • 7Jadhav R, Bhide SV, Prabhudesai PS. Assessment of the impact strength of the denture base resin polymerized by various process- ing techniques [ J ]. Indian J Dent Res,2013,24 ( 1 ) : 19 - 25.
  • 8Azzarri M J, Cortizo MS, Alessandrini JL. Effect of the curing condi-tions on the properties of an acrylic denture base resin microwave- polymerised [ J ]. J Dent,2003,31 (7) :463 - 468.
  • 9Kawaguchi T, Lassila LV, Vallittu PK, et al. Mechanical properties of denture base resin cross-linked with methacrylated dendrimer [J]. Dent Mater,2011,27(8) :755 -761.
  • 10Singh RD, Gautam R, Siddhartha R,et al. High performance liq- uid chromatographic determination of residual monomer released from heat-cured acrylic resin. An in vivo study [ J]. J Prosth- odont,2013,22 (5) :358 - 361.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部