摘要 The inlet temperatures of gas turbines are generally increasing over time,so conventional cooling methods are likely to approach their useful limits.It is therefore essential to investigate novel cooling methods.Based on the theory of heat transfer enhancement,a novel film cooling method for gas turbine blades using a chemical heat sink is proposed.In this method,the endothermic reaction of an NH 3 cooling stream heated by the main gas stream takes place,reducing the convective heat transfer between the mainstream and the blades.Therefore,film cooling effectiveness is improved.To test the feasibility of the proposed method,numerical simulations were conducted,using the classical flat plate with a 30 degree angled cylindrical hole(diameter,D).Film cooling effectiveness at different blowing ratios(M = 0.5,1.0,and 1.5) were computed and compared with the results of conventional cooling methods.The simulation results show that the proposed method can enhance film cooling effectiveness not only in the stream-wise direction,but also in the span-wise direction.The span-averaged film effectiveness is improved in the presence of a chemical heat sink,with the value of X/D(the ratio of downstream distance from the center of the film hole to the diameter of the film hole) increasing downstream of the film hole.The novel film cooling approach showed the best performance at M = 0.5. The inlet temperatures of gas turbines are generally increasing over time, so conventional cooling methods are likely to approach their useful limits. It is therefore essential to investigate novel cooling methods. Based on the theory of heat transfer enhancement, a novel film cooling method for gas turbine blades using a chemical heat sink is proposed. In this method, the endothermic reac- tion of an NH3 cooling stream heated by the main gas stream takes place, reducing the convective heat transfer between the main- stream and the blades. Therefore, film cooling effectiveness is improved. To test the feasibility of the proposed method, numerical simulations were conducted, using the classical flat plate with a 30 degree angled cylindrical hole (diameter, D). Film cooling effectiveness at different blowing ratios (M = 0.5, 1.0, and 1.5) were computed and compared with the results of conventional cooling methods. The simulation results show that the proposed method can enhance film cooling effectiveness not only in the stream-wise direction, but also in the span-wise direction. The span-averaged film effectiveness is improved in the presence of a chemical heat sink, with the value of X/D (the ratio of downstream distance from the center of the film hole to the diameter of the film hole) increasing downstream of the film hole. The novel film cooling approach showed the best performance at M = 0.5.
出处 《Chinese Science Bulletin》 SCIE CAS 2012年第27期3652-3659,共8页
基金 supported by the National Natural Science Foundation of China (50976118) the National Basic Research Program of China(2010CB227302)
关键词 薄膜冷却 散热器 NH3 化学 气膜冷却效率 燃气涡轮机 分解 冷却方法 reaction, heat sink, film cooling, heat transfer, numerical simulation
  • 相关文献

参考文献18

  • 1Kercher D M. A film-cooling CFD bibliography: 1971-1996. lnt J Rotating Machinery, 1998, 4:61-72.
  • 2Bunker R S. A review of shaped hole turbine film-cooling technology J Heat Transfer, 2005, 127:441-454.
  • 3Heidmann J D, Ekkad S V. A novel anti-vortex turbine film-coolinghole concept. J Turbomach, 2008, 130:031020.
  • 4Dhungel A, Lu Y P, Phillips W, et al. Film cooling fi'om a row of holes supplemented with anti vortex holes. J Turbomach, 2009, 131: 021007.
  • 5Heidmann J D. A numerical study of anti-vortex film-cooling designs at high blowing ratio. Technical Report, Gas Turbine Technical Con- gress, National Aeronautics and Space Administration. 2008.
  • 6Gr.f L, Kleiser L. Large-eddy simulation of double-row compound- angle film cooling: Setup and validation. Comput Fluids, 2011, 43: 58-67.
  • 7Na S, Shih T I. Increasing adiabatic tilm-cooling effectiveness by using an upstream ramp. J Heat Transfer, 2007, 129:464-471.
  • 8Nasir H, Acharya S, Ekkas S V. Improved film cooling from cylin- drical angled holes with triangular tabs: Effect of tab orientations, lnt J Heat Fluid Flow, 2003, 24:657-668.
  • 9Ghorab M G. Film cooling effectiveness and net heat flux reduction of advanced cooling schemes using thermochromic liquid crystal. Appl Therm Eng, 2011, 31:77-92.
  • 10Ghorab M G, Hassan I G. An experimental investigation of a new hybrid film cooling scheme. Int J Heat Mass Transfer. 2010, 53: 4994-5007.