摘要
为了保证辐射监测数据的准确,江苏省辐射环境监测管理站组织了2011年全省环境γ辐射剂量率测量比对。结果表明,22台仪器测量结果满意,1台仪器测量数据可疑,所有仪器均未出现不满意或离群结果。测量比对有效地发现了测量存在的问题,保证监测工作结果的准确性。
Quality evaluation of environmental radiation monitoring was performed by Jiangsu Radiation Environmental Monitoring Station with comparison of γ-radiation dose rate monitoring for Jiangsu province in 2011. The analysis results showed that 22 instruments were satisfied and 1 instrument was questionable. Data which measured by all instruments was satisfied and did not appear outlier. The comparison work could effectively find imperfection in measurement to insure quality of γ-radiation monitoring.
出处
《环境监测管理与技术》
2012年第4期67-70,共4页
The Administration and Technique of Environmental Monitoring
关键词
辐射监测
Γ辐射剂量率
测量比对
江苏
Radiation monitoring
γ-radiation dose rate
Measurement comparison
Jiangsu