摘要 A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e^- readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated. A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e^- readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated.
出处 《Chinese Physics C》 SCIE CAS CSCD 2012年第9期846-850,共5页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China (10978002) Youth Innovation Foundation of IHEP(H95461JOU2)
关键词 CCD X-RAY readout system CCD, X-ray, readout system
  • 相关文献

参考文献1

二级参考文献7

  • 1D. Matsuura, H. Ozawa, E. Miyata, et al. Development of an analog LSI for readout of X - ray CCDs [ J ]. Nuclear Instruments and Methods in Physics Research A,2007, 570( 1 ) :140 - 148.
  • 2Fangjun Lu. The hard X- ray modulation telescope (HXMT) : mission and its current status[ Z ]. AAPPS Bulletin. 2009, 19(2) :36 -38.
  • 3CCD47 - 10 .4.[MO back illuminated compact pack high performance CCD sensor [ Z ]. Datasheet, e2v Inc. , 2006.
  • 4Christian C. ENz, Gabor C. Tomes. Circuit technique for reducing the effects of Op - Amp imperfections: autozeroing, correlated double sampling and chopper stabilization [ J ]. Proceeding of the IEEE, 1996, 84 ( 11 ) : 1584 - 1614.
  • 5A. Yamashita, J. Dotani, M. Bautz, et al. Radiation damage to charge coupled devices in the space envi- ronment [ J ]. Nuclear Instruments and Methods in Physics Research A, 1997, 44 ( 3 ) : 847 - 853.
  • 6D. Matsuura, Development of ASICs for multi -read- out X - ray CCDs [ D ]. PH. D Dissertation, Osaka Univ. Japan, 2009.
  • 7E. Miyata, C. Natsukari, D. Akutsu, et al. Fast and flexible CCD -driver system using fast DAC and FP- GA [ J ]. Nuclear Instruments and Methods in Physics Research A,2001,459:157 - 164.