期刊文献+

肺内孤立灶大体肿瘤体积CT不同扫描方式比较 被引量:3

A comparison of the different CT scanning modes on the GTV delineation of the solitary pulmonarylesion
原文传递
导出
摘要 目的比较cT不同扫描方式对肺内孤立病灶大体肿瘤体积(GTV)勾画影响,探讨螺旋扫描在CT模拟定位中的可行性。方法对16例周围型或转移性肺癌分别行轴位(A)、螺旋(S)CT扫描,比较GTV A、GTV S大小和位置差异(配对t检验),计算GTVA、GTV。匹配指数(MI)及与体积相关性(两变量相关分析)。结果GTV A 、GTV S大小分别为8.95、9.38cm^3(t=0.43,P=0.667)。GTVA、GTV。等中心点坐标值x轴分别为6.80、6.81cm(t=0.27,P=0.794),Y轴分别为36.19、36.05cm(t=0.37,P=0.717),z轴分别为4.99、4.96cm(t=0.65,P=0.526)。GTVA和GTV。等中心点至坐标原点距离相似(38.31am:38.23cm,t=0.47,P=0.646)。GTVA与GTV3的MI为0.36(0~0.77),MI与体积显著相关(r=0.587,P=0.017)。结论轴位与螺旋CT扫描方式确定肺内孤立灶GTV的MI与其有相关性,螺旋扫描速度更快,在肺内孤立灶CT模拟定位中具有可行性。 Objective To explore the influence of the CT scanning mode on the gross tumor volume (GTV) delineation of solitary pulmonary lesion (SPL) , and to evaluate the feasibility of the spiral CT scan in CT simulation. Methods Sixteen patients with SPL underwent axial scan, spiral scan during free breathing. Compare the target position, volume between GTV. and GTVA (paired t-test). The matching index (MI) between GTVs and GTVA and correlations between MI and the tumor volume were calculated ( bivariate correlation analysis). Results GTV. and GTVA volume was 8. 95 em3 and 9. 38 cm^3 ( t = 0.43, P =0. 667) , respectively. The eentroid position for GTVs and GTVA in x,y and z axises were 6. 80 cm and 6. 81 em (t =0. 27,P =0.794), 36. 19 cm and 36.05 cm (t =0. 37,P =0.717) , and 4. 99 cm and 4. 96 cm ( t = 0. 65, P = 0. 526 ) , respectively. There were also no statistically significant difference in the distance between the centroidal position and origin of coordinates for GTV. and GTVA (38.31 em: 38. 23 cm, t = 0. 47 ,P = 0. 646). MI between GTVs and GTVA was 0. 36 (range 0 -0. 77 ), correlated with the tumor volume ( r = 0. 587, P = 0. 017 ). Conclusions There was no significant difference between the axial scan and spiral scan in the GTV volume and position for SPL, but MI between GTV. and GTVa were small. A correlation was found for the MI between GTV. and GTVA with the tumor volume. Spiral CT scan was more timesaving, and was feasible in CT simulation scan.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2012年第5期436-438,共3页 Chinese Journal of Radiation Oncology
基金 2011年山东省自然科学基金(ZR2011HM004) 山东省科学技术发展计划项目(2007GG3WZ02047)
关键词 体层摄影术 x线计算机 肺肿瘤 孤立灶 大体肿瘤体积 Tomography, X-ray computed Lung neoplasms, solitary lesion Gross tumorvolume
  • 相关文献

参考文献10

  • 1Bosmans G, Van Baardwijk A, Dekker A, et al. Intra-patient variability of rumor volume and tumor motion during conventionally fractionated radiotherapy for locally advanced on-small-cell lung cancer:a prospective clinical study. Int J Radiat Oncol Biol Phys, 2006,66:748-753.
  • 2于甬华,吴玉芬,郭守芳,王仁本,李文武,李宝生.呼吸运动对周围型肺癌位置的影响及其数学模型的建立[J].中华放射肿瘤学杂志,2004,13(2):83-84. 被引量:20
  • 3Cheung PC, Sixel KE, Tirona R, et al. Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC). Int J Radiat Oncol Biol Phys,2003 ,57 :1437-1442.
  • 4Wang L, Hayes S, Paskalev K, et al. Dosimetric comparison of stereotactic body radiotherapy using 4DCT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage. Radiother Oncol, 2009,91:314-324.
  • 5Shih HA, Jiang SB, Aljarrah KM, et al. Internal target volume determined with expansion margins beyond composite gross tumor volume in three dimensional conformal radiotherapy for lung cancer. Int J Radiat Oncol Biol Phys,2004,60:613-622.
  • 6李贤富,谭榜宪,柳弥,罗玉军,周业琴,胡劲,马代远.CT扫描对靶点位置精确度影响分析[J].中华放射肿瘤学杂志,2009,18(2):142-145. 被引量:1
  • 7Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real- time measurement of 3D tumor motion in lung during to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys ,2002,53:822-834.
  • 8Nakamura M, Narita Y, Matsuo Y, et al. Geometrical differences in target volume between slow CT and 4DCT imaging in stereotactie body radiotherapy for lung tumors in the upper and middle lobe. Med Phy,2008,35:4142-4148.
  • 9尚东平,李明焕,李建彬,尹勇,于金明,杜君.四维CT技术确定肺内孤立性病灶靶体积应用[J].中华放射肿瘤学杂志,2011,20(5):417-419. 被引量:12
  • 10Ezhil M, Vedam S, Baiter P, et ai. Determination of patient- specific internal gross tumor volumes for lung cancer using four- dimensional computed tomography. Radiat 0ncol,2009,4:1-14.

二级参考文献22

共引文献30

同被引文献24

  • 1McWilliams A, Tammemagi MC, Mayo J R,et al. Probability of cancer in pulmonary nodules detected on first screening CT [J]. New England Journal of Medicine, 2013, 369 (10): 910-919.
  • 2Noffke CE, Farman AG, Van der Linde A, et al. Responsible use of cone beam computed tomography: minimising medico legal risks[J]. SADJ: Journal of the South African Dental Association Tydskrif Van Die Suid Afrikaanse Tandheelkundige Vereniging, 2013,68( 6 ) : 256,258-259.
  • 3Shimizu S, Shirato H, Kagei K, et al. Impact of respiratory movement on the computed tomographic images of small lung tumors in three dimensional(3D)radiotherapy[J]. International Journal of Radiation Oncology Biology Physics, 2000,46 (5) : 1127 -1133.
  • 4Chen GT, Kung JH, Beaudette KP. Artifacts in computed tomography scanning of moving objects [J]. Seminars in Radiation Oncology, 2004,14 ( 1 ) : 19-26.
  • 5Nakamura M, Narita Y, Sawada A, et al. Impact of motion velocity on four-dimensional target volumes: A phantom study [J]. Medical Physics, 2009,36(5) :1610-1617.
  • 6Giraud P, Yorke E, Jiang S, et al. Reduction of organ motion effects in IMRT and conformal 3D radiation delivery by using gating and tracking techniques [J]. Cancer/Radiothfirapie, 2006,10(5):269-282.
  • 7Persson GF, Nygaard DE, Brink C, et al. Deviations in delineated GTV caused by artefacts in 4DCT[J]. Radiotherapy and Oncology,2010,96(1) :61- 66.
  • 8Yamamoto T, Langner U, Loo Jr BW, el al. Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients[J]. International Journal of Radiation Oncology Biology Physics, 2008, 72 (4): 1250-1258.
  • 9Erridge SC,Seppenwoolde Y, Muller SH,et al. Portal imaging to assess set up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non small cell lung cancer[J]. Radiotherapy and ()neology, 2003,66 ( 1 ) ; 75-85.
  • 10Geramifar P, Zafarghandi MS, G-hafarian P, et al. Respiratory Induced Errors in Tumor Quantification and Delineation in CT Attenuation-Corrected PET Images: Effects of Tumor Size, Tumor I.oeation, and Respiratory Tracez A Simulation Study Using the 4D XCAT Phantom[J]. Molecular Imaging and Biology, 2013 : 1-11.

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部