期刊文献+

三相光伏并网逆变器控制策略 被引量:56

Control Strategy Study for Three Phase Photovoltaic Grid-Connected Inverters
下载PDF
导出
摘要 在三相光伏并网逆变应用中,如何改善并网电流质量是备受关注的问题。采用LCL滤波器并网虽然提高了滤波效果,减小了滤波器体积,但是控制变得复杂。结合现有控制方法,本文提出了在dq同步旋转坐标系下带有电网电压前馈的比例积分(PI)级联比例谐振(PR)控制思路。建立了dq系下的三相逆变器模型,进行了控制器的分析推导,采用电压前馈改善了并网接入时的动态特性,通过PI实现了并网电流的无静差跟踪控制,级联PR实现了对特定谐波分量的有效抑制。最后,进行了仿真及在实际100kW光伏阵列下的并网逆变测试,实验结果表明该控制方案可以实现并网电流的平滑起动,能有效地降低并网电流的谐波含量。 In the application of three phase photovoltaic gird-connected inverters,how to meliorate quality of grid current is an key issue concerned.Adopting LCL filter to connect inverters with grid brings about a good filtering effect,but it makes control complex.Considering existing control method,in this paper,a strategy that cascaded proportion integrity(PI)and proportion resonation(PR)with grid voltage feed forward based on dq synchronous rotate frame is proposed.The model of three phase inverter is founded and controller was analyzed and derived.This strategy meliorated the dynamic characteristics of connecting grid by feed forward,achieved zero error tracking using PI,and suppressed harmonics currents effectively via PR.Last,simulation and experiment on a 100kW PV array grid-connected inverter are done.The results show that this proposed strategy achieves smooth grid current starting and fewer harmonics current.
出处 《电工技术学报》 EI CSCD 北大核心 2012年第8期64-70,共7页 Transactions of China Electrotechnical Society
关键词 光伏并网逆变 dq旋转坐标系 比例积分+比例谐振级联 电压前馈 特定谐波抑制 Photovoltaic gird-connected inverter dq rotate frame cascaded PI+PR voltage feed forward specific harmonics suppression
  • 相关文献

参考文献12

  • 1Karshenas Hamid R, Saghafi Hadi. Basic criteria in designing lcl filters for grid connected converters[C]. IEEE International Symposium on Industrial Electronics, 2006: 1996-2000.
  • 2Liu Fei, Zhou Yan, Duan Shanxu, et al design of a two-current-loop controller grid-connected inverter system with LCL Paralneter used in a IEEE Transactions on Industrial Electronics, (11): 4483-4491 filter [J]. 2009, 56.
  • 3Teodorescu R, Blaabjerg F, Borup U, et al. A new control structure for grid connected LCL PC inverters with zero steady state error and selective harmonic compensation[C]. Applied Power Electronics Conference and Exposition, 2004:580-586.
  • 4Jung Eunsoo, grid-connected Sul Seung Ki single-phase Implementation of inverter based on FPGA[C]. Applied Power Electronics Conference and Exposition, 2009:889-893.
  • 5Timbus A V, Ciobotaru M, Teodorescu R, et al. Adaptive resonant controller for grid-connected converters in distributed power generation systems [C]. Applied Power Electronics Conference and Exposition, 2006: 1601-1606.
  • 6赵清林,郭小强,邬伟扬.单相逆变器并网控制技术研究[J].中国电机工程学报,2007,27(16):60-64. 被引量:247
  • 7Se Kyo Chung. A phase tracking system for three phase utility interface inverters[J]. IEEE Transactions on Industrial Electronics, 2000, 15 (3): 431-438.
  • 8Timbus A, Teodorescu R, Blaabjerg F, et al. Synchronization methods for three phase distributed power generation systems[C]. Power Electronics Specialists Conference, 2005: 2474-2481.
  • 9Zhang Richard. High performance power converter systems for nonlinear and unbalanced load source[D]. Blackburg, Virginia: Faculty of the Polytechnic Institute and State University Virginia 1998.
  • 10Shen Guoqiao, Zhu Xuancai, current feedback PR control Chen Min, et al. A new strategy for connected vsi with an LCL filters[C]. Applied Power Electronics Conference and Exposition, 2009:1564-1569.

二级参考文献31