期刊文献+

加热时间对铜导线一次短路熔珠金相组织的影响 被引量:3

An Metallographic Microcosmic Analysis on Primary Short Circuited Melted Beads of Copper Wire Heated Different Time
下载PDF
导出
摘要 为考查加热时间对铜导线一次短路熔珠金相显微组织的影响,实验模拟室内火灾环境,在500℃下对熔珠加热不同时间后进行自然和喷水冷却,通过观察自然和喷水冷却熔珠的金相组织,研究加热时间对一次短路熔珠金相组织的影响。得出一次短路熔珠金相组织随加热时间的变化规律,为火场中铜导线一次短路熔珠的鉴定提供依据。 In this experiment,simulating real fire scene,primary short circuited melted beads of different diameter were made by trace evidence test-bed system.In addition to this,simulating indoor fire thermal environment by box-type resistance furnace,beads heated at 500℃ for different time were made.Contrasting the beads formatted under natural cooling condition and water cooling condition,the result shows that different cooling condition has a great impact on the microstructure of primary short circuited beads.Based on the microstructure analysis of primary short circuited beads formatted under different cooling conditions,the changing regularity of the different microstructure of primary short circuited beads with different cooling conditions is drawn.
作者 杨屹茂
机构地区 阳泉市消防支队
出处 《武警学院学报》 2012年第8期89-91,共3页 Journal of the Armed Police Academy
关键词 一次短路熔珠 金相组织 冷却条件 铜导线 primary short circuited beads microstructure cooling condition copper lead
  • 相关文献

参考文献5

二级参考文献6

  • 1段虹.金相试样显微组织的显示原理[J].天津职业技术师范学院学报,1997,7(2):40-41. 被引量:4
  • 2王希庆 韩宝玉 邸曼.电气火灾现场勘查与鉴定技术指南[M].沈阳:辽宁大学出版社,1996..
  • 3邸曼.火灾现场铜导体熔痕表面微区SEM和EDS鉴定技术[A],中国消防协会火灾原因调查专业委员会第三届第二次年会暨学术研讨会[C].
  • 4北京市公安局消防局(编).2001年火灾年报.
  • 5刘国勋.金属学原理[M]冶金工业出版社,1980.
  • 6邵学民,盛涛,张树椿,孙忠武.二次短路熔痕在认定起火部位中的作用[J].消防科学与技术,2002,21(3):68-68. 被引量:7

共引文献33