期刊文献+

脉搏信号调理电路设计 被引量:5

Design of circuit for conditioning the pulse signals
下载PDF
导出
摘要 脉搏作为人体重要的生理及病理指标之一,具有重要的医学研究价值。针对其信号微弱、频率低且易受干扰的特点,提出了信号调理电路设计的要求;针对性地选择元器件并设计硬件电路,其中包括:一级放大电路、调零电路、50Hz限波电路、带通滤波电路及二级放大电路;最后对所设计的硬件电路进行实际测试。测试结果表明,该调理电路具有输出波形稳定、噪声小和共模抑制比高的特点,提高了脉搏信号采集的精度。 Pulse is one of the most important index of the human physiology and pathology, and provided with important medical researchful value . Based on the characteristic of weak , low frequency and easily can be disturbed of pulse signals, the request of conditioning circuit for pulse signals is proposed, and the necessary compinents are elected in accordance with the characters of pulse, and the circuit is design. There are the circuit of prepose amplification, the circuit of zero, the circuit of restricting the signals 50 Hz, the circuit of band-pass filter and the circuit of secondary amplification. The circuit of hardware designed has been tested, and the measurement shows that the conditioning circuit of pulse signals possesses the advantages of high CMMR(common model restrain ration), low noise, the output is stabilization, and has enhanced the precision of collection for pulse signals.
出处 《电子技术应用》 北大核心 2012年第9期46-49,53,共5页 Application of Electronic Technique
基金 陕西省教育厅专项科研计划基金资助项目(09JK492) 陕西省科学技术研究发展计划项目(2009K08-10)
关键词 脉搏 信号调理 电路设计 pulse conditioning signals design of circuit
  • 相关文献

参考文献8

二级参考文献51

共引文献66

同被引文献51

  • 1刘文,唐辉,商洪涛.光电传感器在脉搏采集中的研究[J].中国医学装备,2005,2(9):22-23. 被引量:13
  • 2戴君伟,王博亮.光电脉搏传感器的研制和噪声分析[J].现代电子技术,2006,29(2):78-80. 被引量:25
  • 3杨日杰,田宝国,何友.一种主/被动声呐目标回波信号模拟器的研制[J].仪器仪表学报,2006,27(3):229-232. 被引量:15
  • 4王丽英.基于光电技术的脉搏测量方法[J].国外电子元器件,2006(5):32-34. 被引量:5
  • 5张立 刘昆.基于FPGA的采样与控制系统设计.电子测量与仪器学报,2008,.
  • 6CHU D,HUFNAGLE LC,Jr.Time varying gain (TVG) measurements of a multibeam echo sounder for applications to quantitative acoustics[C] .OCEANS 2006,2006,18-21:1-5.
  • 7Gu D, Kelly TN, WU X,et al. Blood pressure and risk of cardiovascular disease in Chinese men and women[J].American journal of hypertensi on, 2008,21(3). 255-272.
  • 8Lass J,Meigas K,Karai D,et al. Continuous blood pressure monitoring during exercise using pulse wave transit time measurement[C]. USA:Proceedings of the 26th Annual International Conference of the IEEE EMBS,San Francisco,CA, September, 2004:1-5.
  • 9GAN K,PENG XW,ZHAO ZD.Design of Intelligent Display Meter based on ARM[J]. Industrial Instrumentation and Control Systems, 2013,241-244(1-4) 525-528.
  • 10Marl M,Rajan S,Bolic M,et al.Blood pressure estimation using maximum slope of oscillometric pulses[J].Conf Proc IEEE Eng Med Biol Soc, 2012,2012: 3239- 3242.

引证文献5

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部