期刊文献+

ф9800mm焦炭塔裂纹应力分析 被引量:2

STRESS ANALYSIS OF CRACKS ON ф9800MM COKE TOWER
下载PDF
导出
摘要 某石化公司ф9800mm焦炭塔是国内最大的焦炭塔,塔裙连接处采用一种新型焊接结构,投入使用8个月,在塔裙连接处的应力槽部位出现裂纹,文章针对裂纹产生部位建立有限元模型,进行应力分析及评定。结果表明,由于温度变化产生的热应力是导致出现裂纹的主要原因。 The ф9800mm coke tower of a petrochemical company is the largest one in China.The tower used a new welded structure to link the tower and skirt.After being put into use for eight months,it was found that there were cracks near the stress relief slots.This paper establishes the finite element model according to the parts where cracks appeared.It carries out stress analysis and assessment.The results indicate that the thermal stress caused by the change of temperature is the main reason for the cracks.
出处 《石油化工设备技术》 CAS 2012年第4期7-10,69,共4页 Petrochemical Equipment Technology
关键词 焦炭塔 裂纹 热应力 应力分析 Coke tower Crack Thermal stress Stress analysis
  • 相关文献

参考文献5

  • 1韩玉梅,肖文丽.一种新型焦炭塔裙座结构介绍[J].石油化工设备技术,2008,29(2):12-13. 被引量:7
  • 2中国石油天然气华东勘察设计研究院.一种大型容器底封头与裙座的焊接构件[P].中国专利:200310121385.9,2003-12-16.
  • 3余伟炜,高炳军.ANSYS在机械与化工装备中的应用[M].第二版.北京:中国水利水电出版社.2006.47-50,l14一149.
  • 4JB 4732-1995,钢制压力容器分析设计标准[S].
  • 51996 API. COKE DRUM SURVEY(EB/CD). Final Report July 21, 1998.