摘要
对6kV配电网线路外力破坏事故进行对比分析,结果证明2011年外力破坏事故大幅增加。运用典型事故案例进行剖析,找出破坏事故的共性和特点。提出了防范措施,有助于决策部门采取防范措施,以减少电力线路外力破坏事故的发生,提高配网供电可靠性。
Comparative analysis was made to external damage accidents of power lines in 6 kV distribution network,the result showed that the external damage accidents increased significantly in 2011.The typical accident cases were used for analysis to find their similarity and characteristics.The measures of precaution were proposed,which will help the decision-making departments to adopt measures of precaution,so to reduce occurrence of external damage accidents of power lines and improve liability of distribution network in power supplying.
出处
《炼油与化工》
2012年第4期19-21,62,共3页
Refining And Chemical Industry
关键词
6
KV配电网
外力破坏
事故分析
防范措施
6kV distribution network
external damage
accident analysis
measures