摘要
通过对某变电站110 kV子系统的南风线进行事故树分析,得出安全评价结果,并依据评价结果对该变电站110 kV子系统提出客观合理的安全对策措施,为变电站的安全运行提供依据和参考。
This paper uses the fault tree to analyze 110 kV subsystem. Based on the analysis, the safety evaluation results are obtained, and safety measures for the subsystem are proposed objectively and reasonably, which provides basis and reference for the safe operation.
出处
《山西电力》
2012年第4期29-32,共4页
Shanxi Electric Power
关键词
停电事故
最小径集
最小割集
事故树分析
power outage
minimal radius set
minimum cut set
fault tree analysis