期刊文献+

陶板幕墙抗震性能振动台试验研究 被引量:3

Shaking table test on seismic behavior of ceramic plate curtain wall
下载PDF
导出
摘要 通过钢框架外挂足尺陶板幕墙模型的振动台实验,研究了陶板幕墙的抗震性能。实验中分别输入El-Centro地震波、人工波及0.5~50Hz的白噪声波。实验结果表明,最大层间位移角为1/237,表明陶板幕墙系统具有良好的抗震性能,符合抗震设计要求。实验过程中,输入同样加速度的El-Centro地震波、人工波后便输入白噪声波,以检测结构自振频率的变化,最后拟合出频率变化曲线,发现当地震加速度达到300Gal以后,结构自振频率基本不再变化。 This article studies on seismic performance of a ceramic plate curtain wall by shaking table of a steel frame hanging a full scale ceramic plate curtain wall model. In the test, E1-Centro seismic waves, artificial wave and 0.5 -50Hz white noise wave were inputted. Results show that the maximum story drift angle is 1/237, it means that the seismic performance of ceramic plate curtain wall system is good , it satisfies the seismic design requirements. In the test, the white noise wave was inputted just after the E1-Centro seismic waves and artificial wave which have the same acceleration to detect the changes in the natural frequency of structure. Finally, we fitted out the frequency curve, and it shows that when the earthquake acceleration reaches 300 Gal, the natural frequency of the structure is no longer changeable.
出处 《世界地震工程》 CSCD 北大核心 2012年第3期11-14,共4页 World Earthquake Engineering
关键词 陶板幕墙 振动台试验 抗震性能 自振频率 ceramic plate curtain wall shaking table etest seismic performance natural frequency
  • 相关文献

参考文献3

二级参考文献22

  • 1曹资,张毅刚,刘景元,等.玻璃幕墙地震反应的振动台试验研究[C]∥第五届全国地震工程学术会议.北京:地震出版社,1998.876-871.
  • 2谢士涛,赵西安.建筑幕墙抗震性能的试验研究[C]//2003年首届全国建筑装饰行业科技大会文集.北京:建筑工业出版社,2003.312-315.
  • 3JGJ102-2003.玻璃幕墙工程技术规范[S].[S].,2003..
  • 4CECS 101:98,建筑瓷板装饰工程技术规程[S].
  • 5JGJ 133-2001,金属与石材幕墙工程技术规范[S].
  • 6GB/T 18575-2001,建筑幕墙抗震性能振动台试验方法[S].
  • 7赵西安.玻璃幕墙的结构设计、第14届全国高层建筑结构学术交流会,1996.
  • 8中华人民共和国国家标准.建筑抗震设计规范(GBJ11-89).北京:中国建筑工业出版社,1989.
  • 9Xu Zhonggen, etc. Shaking table test of dry hanging granite curtain wall. Proceedings of International Symposium on Theory and Application of Structural Engineering Test Method, November 8 - 10, 1999, Beijing,China.
  • 10施卫星,徐磊.玻璃幕墙地震作用研究、第15届全国高层建筑结构学术交流会,1998同济大学试验研究报告.花岗岩幕墙抗震性能试验报告,2000.

共引文献19

同被引文献30

  • 1于永清.四川电网汶川地震电力设施受灾调研分析.电网技术,2008,32(11):1-6.
  • 2VANZI I.Seismic reliability of electric power networks:methodology and application[J].Structural Safety,1996,18(4):311-327.
  • 3THORNBERRY L R,HARDY R.Seismic simulation test program on type CGCB 230 k V disconnect switch[R].Ala:Wyle Laboratories,1997.
  • 4XIE Qiang,ZHU Ruiyuan.Damage to electric power grid infrastructure caused by natural disasters in China[J].IEEE Power and Energy Magazine,2011,9(2):28-36.
  • 5GB/T 13540—2009高压开关设备和控制设备的抗震要求[S].2009.
  • 6GB/T 2424.25—2000电工电子产品环境试验第三部分:试验导则地震试验方法[S].2000.
  • 7GB 50260—2013电力设施抗震设计规范[S].2013.
  • 8ANG A S,PIRES J,VILLAVERDE R,et al.Seismic probabilistic reliability assessment of electric power transmission systems[J].Reliability Engineering and System Safety,1996,51(1):7-12.
  • 9IEEE Std 693—2005 Recommended practice for seismic design of substations[S].2005.
  • 10程永锋,朱全军,卢智成.变电站电力设施抗震措施研究现状与发展趋势[J].电网技术,2008,32(22):84-89. 被引量:112