摘要 介绍了加速器驱动次临界系统(ADS)注入器Ⅱ束流聚焦单元超导螺线管的初步测试。该测试在高度1 600mm、直径510mm的垂直杜瓦中,利用型号为cryogenic sms的超导电源对磁体进行了励磁,并利用霍尔探头测试了其轴向磁场分布情况和漏场情况,其中心磁场励磁后可达8.20T,漏场分布和计算值的相对误差小于10%。同时,对励磁过程中骨架的应力应变状态做了测试。对测试结果的分析表明,骨架结构设计合理,应变状态变化平稳,磁体低温稳定性能良好。 The preliminary test of the superconducting solenoid for ADS injector tl has been carried out in order to measure its performances. A vertical dewar with height 1 600 mm and outer diameter 510 mm was employed for this test. The magnet was energized by a cryogenic sms superconducting magnet current source. The axial magnetic distribution and leakage field were also tested through hall probes. The center field can be excited up to 8.20 T and the relative diviation between the measured value and the calculated value of the stray and leakage field is less than 10%. The measurements of the strain and stress status of the magnet skeleton show that the distortion is small and the mechanical performance is robust.
出处 《原子核物理评论》 CAS CSCD 北大核心 2012年第3期244-247,共4页 Nuclear Physics Review
基金 国家自然科学基金资助项目(NSF91026001)~~
关键词 超导螺线管 加速器驱动次临界系统 垂直测试 磁场测量 SC solenoid accelerator driven sub-critical system~ vertical test magnetic {ield measurement
  • 相关文献

参考文献5

  • 1WANG Zhijun, HE Yuan, LIU Yong, et al. Chinese Physics C, 2012, in press.
  • 2SUN Hong, ZHAO Shengchu, GE Mingqi, etal. Chinese Physics C, 2005, 29(10): 989.
  • 3YANG Xiaoliang, MA Lizhen,Wu Wei, et al. Chinese Physics C, 2012.
  • 4WU Wei, HE Yuan, MA Lizhen, et al. Chinese Physics C, 2010, 84(7): 978.
  • 5Cryoperm Specifications[EB/OL:. [2012-01-05:. http:// www. cryopermshielding, com/cryoperm-specifications, html.

同被引文献10

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部