摘要
介绍了加速器驱动次临界系统(ADS)注入器Ⅱ束流聚焦单元超导螺线管的初步测试。该测试在高度1 600mm、直径510mm的垂直杜瓦中,利用型号为cryogenic sms的超导电源对磁体进行了励磁,并利用霍尔探头测试了其轴向磁场分布情况和漏场情况,其中心磁场励磁后可达8.20T,漏场分布和计算值的相对误差小于10%。同时,对励磁过程中骨架的应力应变状态做了测试。对测试结果的分析表明,骨架结构设计合理,应变状态变化平稳,磁体低温稳定性能良好。
The preliminary test of the superconducting solenoid for ADS injector tl has been carried out in order to measure its performances. A vertical dewar with height 1 600 mm and outer diameter 510 mm was employed for this test. The magnet was energized by a cryogenic sms superconducting magnet current source. The axial magnetic distribution and leakage field were also tested through hall probes. The center field can be excited up to 8.20 T and the relative diviation between the measured value and the calculated value of the stray and leakage field is less than 10%. The measurements of the strain and stress status of the magnet skeleton show that the distortion is small and the mechanical performance is robust.
出处
《原子核物理评论》
CAS
CSCD
北大核心
2012年第3期244-247,共4页
Nuclear Physics Review
基金
国家自然科学基金资助项目(NSF91026001)~~
关键词
超导螺线管
加速器驱动次临界系统
垂直测试
磁场测量
SC solenoid
accelerator driven sub-critical system~ vertical test
magnetic {ield measurement