期刊文献+

Simulation of biatrial conduction via different pathways during sinus rhythm with a detailed human atrial model 被引量:3

Simulation of biatrial conduction via different pathways during sinus rhythm with a detailed human atrial model
原文传递
导出
摘要 In order to better understand biatrial conduction,investigate various conduction pathways,and compare the differences between isotropic and anisotropic conductions in human atria,we present a simulation study of biatrial conduction with known/assumed conduction pathways using a recently developed human atrial model.In addition to known pathways:(1) Bachmann's bundle(BB),(2) limbus of fossa ovalis(LFO),and(3) coronary sinus(CS),we also hypothesize that there exist two fast conduction bundles that connect the crista terminalis(CT),LFO,and CS.Our simulation demonstrates that use of these fast conduction bundles results in a conduction pattern consistent with experimental data.The comparison of isotropic and anisotropoic conductions in the BB case showed that the atrial working muscles had small effect on conduction time and conduction speed,although the conductivities assigned in anisotropic conduction were two to four times higher than the isotropic conduction.In conclusion,we suggest that the hypothesized intercaval bundles play a significant role in the biatrial conduction and that myofiber orientation has larger effects on the conduction system than the atrial working muscles.This study presents readers with new insights into human atrial conduction. In order to better understand biatrial conduction, investigate various conduction pathways, and compare the differences between isotropic and anisotropic conductions in human atria, we present a simulation study of biatrial conduction with known/assumed conduction pathways using a recently developed human atrial model. In addition to known pathways: (1) Bachmann's bundle (BB), (2) limbus of fossa ovalis (LFO), and (3) coronary sinus (CS), we also hypothesize that there exist two fast conduction bundles that connect the crista terminalis (CT), LFO, and CS. Our simulation demonstrates that use of these fast conduction bundles results in a conduction pattern consistent with experimental data. The comparison of isotropic and anisotropoic conductions in the BB case showed that the atrial working muscles had small effect on conduction time and conduction speed, although the conductivities assigned in anisotropic conduction were two to four times higher than the isotropic conduction. In conclusion, we suggest that the hypothesized intercaval bundles play a significant role in the biatrial conduction and that myofiber orientation has larger effects on the conduction system than the atrial working muscles. This study presents readers with new insights into human atrial conduction.
出处 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2012年第9期676-694,共19页 浙江大学学报(英文版)B辑(生物医学与生物技术)
基金 Project supported by the National Basic Research Program (973) of China (No. 2007CB512100) the National High-Tech R & D Program (863) of China (No. 2006AA02Z307) the National Natural Science Foundation of China (Nos. 81171421 and 61101046) the Zhejiang Provincial Natural Science Foundation of China (No. Z1080300)
关键词 Cardiac electrophysiology Conduction Human atrial model MODELING 传导途径 模型模拟 心房 人力 心律 各向同性 各向异性 导通时间
  • 相关文献

参考文献70

  • 1Anderson, K.R., Ho, S.Y., Anderson, R.H., 1979. Location and vascular supply of sinus node in human heart. Br. Heart J., 41(1):28-32. [doi:l O. 1136/hrt.41.1.28].
  • 2Anderson, R.H., Cook, A.C., 2007. The structure and components of the atrial chambers. Europace, 9(S6):vi3-vi9. [doi:10.1093/europace/eum200].
  • 3Anderson, R.H., Ho, S.Y., Becker, A.E., 2000. Anatomy of the human atrioventricular junctions revisited. Anat. Rec., 260(1):81-91. [doi: 10,1002/1097-0185(20000901 )260:1 < 61 ::AID-AR90>3.0.CO;2-3].
  • 4Anderson, R.H., Yanni, J., Boyett, M.R., Chandler, N.J., Dobrzynski, H., 2009. The anatomy of the cardiac conduction system. Clin. Anat., 22(1):99-113. [doi:lO. 1002/ca.20700].
  • 5Blanc, O., Virag, N., Vesin, J.M., Kappenberger, L., 2001. A computer model of human atria with reasonable computation load and realistic anatomical properties. IEEE Trans. Biomed. Eng., 48(11):1229-1237. [doi:10. 1109110.959315].
  • 6Boineau, J.P., 1985. Atrial flutter: a synthesis of concepts. Circulation, 72(2):249-257. [doi:10.1161/01.CIR.72,2.249].
  • 7Boineau, J.P., Schuessler, R.B., Hackel, D.B., Miller, C.B., Brockus, C.W., Wylds, A.C., 1980. Widespread distribution and rate differentiation of the atrial pacemaker complex. Am. J. Physiol., 239(3):H406-H415.
  • 8Boineau, J.P., Canavan, T.E., Schuessler, R.B., Cain, M.E., Corr, P.B., Cox, J.L, 1988. Demonstration of a widely distributed atrial pacemaker complex in the human-heart. Circulation, 77(6):1221-1237. [doi:10.1161/O1.ClR.77. 6.1221].
  • 9Bromberg, B.I., Hand, D.E., Schuessler, R.B., Boineau, J.P., 1995. Primary negativity does not predict dominant pacemaker location: implications for sinoatrial conduction. Am. J. Physiol., 269(3):H877-H887.
  • 10Burashnikov, A., Mannava, S., Antzelevitch, C., 2004. Transmembrane action potential heterogeneity in the canine isolated arterially perfused right atrium: effect of Ikr and IkJlto block. Am. J. Physiol., 286(6):H2393- H2400. [doi: 10.11521ajpheart.01242.2003].

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部