期刊文献+

CT结肠镜中的电子清肠:结肠增强滤波

Electronic Cleansing in CT Colonography:Colon Enhancement Filtering
下载PDF
导出
摘要 针对由于口服对比剂的部分容积效应,使得电子清肠存在两种伪影:伪软组织和软组织退化的问题,利用结肠增强滤波来进行电子清肠.首先在确定初始标记物区域时,采用发射射线法,去除伪软组织;然后利用Hessian矩阵的特征值针对不同的结构表现不同的特性,构造结肠软组织增强函数,同时增强空气中和标记物中的软组织.实验表明,该方法能够减轻标记物中软组织退化,去除伪软组织,同时保存夹在标记物和空气之间的褶皱,与手动分割结果的重合率高达91.7%. CT eolonoscopy plays an important role in the early detection of colon cancer. However, because of the partial volume effect of oral contrast agent, electronic cleansing approach tended to suffer from the artifacts of degradation of the soft-tissue structures and the pseudo soft- tissue structures. So, colon enhancement filtering was presented. Firstly, the pseudo soft-tissue was removed by using segment rays in determining initial tagging region phase, then the enhancement function for soft-tissue was constructured with eigenvalue signature of Hessian matrix to enhance the soft-tissue laoth in air and in the tagging regions. The experimental results show that this method can reduce the degradation of the soft-tissue, remove the pseudo soft-tissue and preserve thin folds sandwiched between air and tagging regions. The overlap between the results lay manual and the as-reported segmentations is up to 91.7 %.
出处 《东北大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第9期1364-1368,共5页 Journal of Northeastern University(Natural Science)
基金 国家自然科学基金资助项目(61071213)
关键词 电子清肠 CT结肠镜 部分容积效应 HESSIAN矩阵 结肠增强滤波 electronic cleansing CT colonography partial volume effect Hessian matrix colonenhancement filtering
  • 相关文献

参考文献10

  • 1Nfippi .I, Yoshida H. Fully automated three-dimensional detection of polyps in fecal-tagging CT colonography [ J ]. NIH Public Access, 2007,14(3) :287 - 300.
  • 2Wang Z G, Liang Z G. An improved electronic coloncleansing method for detection of colonic polyps by virtual eolonoscopy [ J ]. IEEE Transactions on Biomedical Engineering, 2006,53(8) : 1635 -1647.
  • 3Wang S, hi L H, Cohen H. An EM approach to MAP solution o{ segmenting tissue with application to CTLbased virtual eolonoscopy [J ]. Medico! Physics, 2008, 35 (12) : 5787- 5799.
  • 4Lakare S, Chen I3, Li L, et al. F lectronic colon e eansing using segmentation rays for virtual colonoscopy [ J ]. Society of Photo-Optical Instrumentation Engineers, 2002, 4683: 412-418.
  • 5Franaszek M, Summers R, Pickhardt P, et al. Hybrid segmentation of colon filled with air and opaeified fluid for CT colonography [ J ], IEEE Transactions on Medical Imaging, 2006,25(3) : 358 - 368.
  • 6Cai W L, Zalis M, Nfippi J, et al. Structure-analysis method for electronic cleansing in cathartic and noncathartic CT colonography[ J ]. Medical Physics, 2008, 35 ( 7 ) : 3259 - 3278.
  • 7Frangi A F, Niessen W J, Vincken K L, et al. Multiscale vessel enhancement filtering[ C] // Medical Image Computing & Computer-Assisted Intervention. New York: Springer Verlag, 1998 : 130 - 137.
  • 8Yoshida H, Nfippi J. Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps [ J ]. IEEE Transactions on Medical Imaging, 2001,20 (12) : 1261- 1274.
  • 9Maxime D, Michel A, Kiyoyuki C, et al. Bone enhancement filtering : application to sinus bone segmentation and simulation of pituitary surgery [ J ]. Computer Aided Surgery, 2006,11 (5) : 247 - 255.
  • 10Cai W L. Propagation shell for segmenting objects with fuzzy boundaries, automatic volume determination and tumor detection using computer tomography: US, tl/943, 577 [P]. 2007 -11 -20.

相关作者