摘要
对某电厂在一次机组的启动过程中电动给水泵多次联锁自动启动的原因进行了分析,针对电动给水泵联锁启动逻辑设计中的缺陷进行了修改完善,从而避免电泵在非必要情况下的联锁启动和启动后对给水系统带来的扰动。
Start the process of a power plant in a unit MDBFP several interlocking automatically start, modified for electric start feed pump in- terlock logic design flaws, and thus avoid electric pump in the non-essentialcase interlock start-up and the water supply system after the start of the disturbance.
出处
《机械管理开发》
2012年第5期81-82,共2页
Mechanical Management and Development