期刊文献+

液相色谱-电化学衍生-光学检测技术研究进展 被引量:1

Progress of Liquid Chromatography-post-column Electrochemical Derivatization and Optical Detection
下载PDF
导出
摘要 综述了以反相键合相为主的高效液相色谱-柱后电化学衍生-荧光检测(RP-HPLC/ED/FD)技术的研究进展。对RP-HPLC/ED/FD存在的主要问题进行了讨论。并介绍了离子色谱-柱后电化学衍生-光学联用装置的构建及其在极性有机物和金属离子的测定方面的应用研究。 This paper reviewed the progress of the reversed-phase high performance liquid chromatography with post-column electrochemical derivatization and fluorescence detection(RP-HPLC/ED/FD. The major problems of the RP-HPLC/ED/FD were discussed. The configuration of a RP-HPLC/ED/FD instrument and its applications in the determination of polar organic compounds and metal ions were also introduced.
出处 《中国无机分析化学》 CAS 2012年第3期1-7,共7页 Chinese Journal of Inorganic Analytical Chemistry
基金 浙江省自然科学基金(Y4090268 LY12B05003)
关键词 高效液相色谱 电化学衍生 荧光 离子色谱 RP-HPLC electrochemical derivatization fluorescence IC
  • 相关文献

参考文献21

  • 1Ibrahim H,Caudron E, Kasselouri A, et al. Interest of fluorescence derivatization and fluorescence probe assisted post-column detection of phospholipids: A short re-view[J]. Molecules, 2010,15(1) :352-73.
  • 2Fedorowski J, LaCourse W R. A review of post-column photochemical reaction systems coupled to electrochemical detection in HPLC[J]. Anal. Chim. Acta, 2010,657(l):l-8.
  • 3Murayama M,Dasgupta P K. Liquid chromatographic determination of nitro- substituted polynuclear aromatic hydrocarbons by sequential electrochemical and fluorescence detection [J]. Anal. Chem. ,1996,68(7) :1226-1232.
  • 4Kuo C T,Chen H W,Lin S T. Trace determination of nitrated polycyclic aromatic hydrocarbons using liquid chromatography with on-line electrochemical reduction and fluorescence detection^J^. Anal. Chim. Acta,2003, 482(2):219-228.
  • 5Meyer J, Liesener A, Gotz S, et al. Liquid chromatography with on-line electrochemical derivatization and fluorescence detection for the determination of phenols[J]. Anal. Chem.,2003,75(4):922-926.
  • 6Hayen H,Karst U. Analysis of phenothiazine and its derivatives using LC/electrochemistry/MS and LC/electrochemistry/fluorescence[J]. Anal. Chem. , 2003 , 75 (18): 4833-4840.
  • 7Li H,Luo W,Zeng Q, et al. Method for the determination of blood methotrexate by high performance liquid chromatography with online post-column electrochemical oxidation and fluorescence detection[J]. J. Chromatogr. B,2007,845(1) :164-168.
  • 8Takezawa K, Tsunoda M, Watanabe N, et al. An automatic analyzer for catecholamines and their 3-o-methyl metabolites using a micro coulometric flow cell as a postcolumn reactor for fluorogenic reaction [J]. Anal. Chem. ,2000,72(17):4009-4014.
  • 9Eickhoff H, Jung G, Rieker A. Oxidative phenol cou-pling-tyrosine dimers and libraries containing tyrosyl peptide dimers[J]. Tetrahedron,2001,57(2) ;353-364.
  • 10Tsunoda M, Takezawa K, Santa T,et al. Simultaneous automatic determination of catecholamines and their 3-o-methyl metabolites in rat plasma by high-performance liquid chromatography using peroxyoxalate chemilumi-nescence reaction[J]. Anal. Biochem.,1999, 269 (2): 386-392.

同被引文献10

  • 1赵先恩,尤进茂,刘洪珍,索有瑞.大鼠血浆中痕量氨基酸的柱前衍生-高效液相色谱串联质谱测定[J].分析化学,2007,35(7):938-944. 被引量:15
  • 2Yoshida H, Nohta H, Harada Y,et al. A simple liquid chromatographic method based on intramolecular exci- mer-forming derivatization and fluorescence detection for the determination of yrosine and *yramine in urineJ. J. Chromatogr. B,2005,821(1) ..88-93.
  • 3Molnar-Perl I. Advances in the high-performance liquid chromatographic determination of phenylthiocarbamyl amino acidsFJ.J. Chromatogr. A,1994,661(1):43-50.
  • 4Bauza T, Blaise A, Daumas F, et al. Determination of biogenic amines and their precursor amino acids in wines of the vall6e du rh6ne by higln performance liquid chroma- tography with precolumn derivatization and fluorimetric de- tection[J. J. Chromatogr. A, 1995,707(2) .. 373-379.
  • 5Nojiri S, Karnata K, Nishiiima M. Fluorescence detec- tion of biotin using post-column derivatization with opa in high performance liquid chromatography E J ]. J. Pharm. Biomed. Anal. , 1998,16(8):1357 1362.
  • 6Dobashi Y, Santa T, Nakagomi K,et al. An automated analyzer for methylated arginines in rat plasma by high performance liquid chromatography with post column fluorescence reaction[J. Analyst, 2002,127 ( 1 ) ; 54 59.
  • 7Gil-Agusti M,Carda Broch S, Monferrer-Pons L,et al. Simultaneous determination of tyramine and tryptamine and their precursor amino acids by micellar liquid chro- matography and pulsed amperometric detection in wines J.J. Chromatogr. A,2007,1156(1) :288-295.
  • 8Wu S, Yang B, Xi L,et al. Determination of phenols with ion chromatography online electrochemical deri vatization based on porous electrode-fluorescence detec tion[J}. J. Chromatogr. A,2012,1229(2) =288-292.
  • 9黄兴振,蒋伟哲,黄敏,吕立,吕聪,巫玲玲,施晓霞.高效液相色谱法测定猫豆中酪氨酸含量[J].中国药业,2009,18(20):23-24. 被引量:6
  • 10穆萨,李影,唐爱国,肖乐东.HPLC-FD法测定重性抑郁障碍患者血清酪氨酸、色氨酸和5-羟色胺[J].临床检验杂志,2011,29(3):161-164. 被引量:2

引证文献1