期刊文献+

包头电网运行风险点分析及改进建议 被引量:2

Analysis of Grid Operating Risk Points in Baotou Area and Improvement Suggestion
下载PDF
导出
摘要 包头地区主、配电网结构相对薄弱,220 kV电网动热稳定问题突出,110 kV电网缺少市区电源点,10 kV配电网局部供电能力不足,互带能力差,运行方式安排困难,包头电网存在事故运行风险点,供电可靠性有待进一步提高。针对包头电网存在的薄弱环节,建议加强500 kV、220 kV网络结构;提高220 kV线路通流能力;增加220 kV变电站的站点分布,增加变电容量;对单电源、单主变变电站及无载调压主变变电站进行改造,增强系统的供电可靠性。 The main and distribution network structure in Baotou area are relatively weak, and 220 kV power thermal stability problems appear sharply, 110 kV power supply is short of urban power point, local power supply capacity of 10 kV distribution network is in shortage, reception load ability is inferior, operation mode arrangement is difficult. Power supply in baotou exist operating risks point and power supply reliability is to be further improved. Suggest to strengthen 500 kV and 220 kV construct network structure, remould 220 kV lines on flow ability, increase site distribution of 220 kV transformer station, and increase the transformer capacity. Meanwhile remould single power, single main transformer station and no load pressure regulating in main transformer stations to strengthen the system reliability of power supply,
机构地区 包头供电局
出处 《内蒙古电力技术》 2012年第4期44-49,共6页 Inner Mongolia Electric Power
关键词 电网检修方式 事故等级 运行风险点 供电可靠性 薄弱环节 overhaul way at power supply accident level operating risks point powersupply reliability weak link
  • 相关文献

参考文献7

  • 1国务院.电力安全事故应急处置和调查处理条例[M].北京:中国电力出版社,2011.
  • 2内蒙古电力(集团)有限责任公司.内电安监[2002]5号文件内蒙古中西部电网事故风险分析报告[M].呼和浩特:内蒙古电力(集团)有限责任公司,2012.
  • 3包头供电局.包头地区电网年度运行方式[M].包头:包头供电局,2012.
  • 4中华人民共和国国家经济贸易委员会.Q/GDW156-2006城市电力网规划设计导则[S].北京:中同电力出版社.2007.
  • 5万千云.电力系统运行技术[M].北京:巾国电力出版社,2004:109一ll1.
  • 6牧仁,邢世英.包头电网风电汇集区域检修方式下的潮流控制分析[J].内蒙古电力技术,2012,30(3):50-53. 被引量:3
  • 7王新学.电力网及电力系统[M].北京:水利电力出版社,1991.193-220.