摘要
为了更好地满足我国新版GMP对药厂洁净室的建设与环境控制的要求,采用新型的智能文丘里阀来控制药厂洁净室的风量-压力参数。通过整改前后系统送风量和静压差的比较与分析,表明智能文丘里阀能行之有效地保证洁净室风量与压力的控制要求。
In order to better meet the requirements of the new GMP for the pharmaceutical clean room construction and environmental control, a new Smart Venturi valve is used to control air volume and pressure in the pharmaceutical cleanroom. Through analyzing and comparing the air volumes and static pressure differences before and after the transformation of the system, the results show that the Smart Venturi valve can effectively ensure the requirements of air volume and pressure control in the cleanroom.
出处
《洁净与空调技术》
2012年第3期32-35,共4页
Contamination Control & Air-Conditioning Technology