以炉内直接加入石灰石进行脱硫的循环流化床锅炉为对象 ,基于GB10 184- 88,结合内江电厂锅炉性能试验的实践 ,参考国外脱硫计算方法 。
This paper proposed a method to determine CFB boiler thermal effciency with direct limestone injection for SO 2 removal,which is based on the Chinese national standards GB10184 and Neijiang 100 MW CFB boiler performance test results as well as SO 2 removal calculation method used in foreign countries.