摘要
介绍6万t/a离子膜装置各工序的特点,并结合运行数据,分析了系统运行的经济性、工艺设计上的优缺点,并提出了注意事项及建议。
The 60kt/a ionic membrane caustic soda process characteristics was introduced. Combined with the operation data, analyzed the system economic operation and the advantages and disadvantages. The attention and suggestions were put forward.
出处
《中国氯碱》
CAS
2012年第8期10-12,共3页
China Chlor-Alkali
关键词
膜极距电解槽
膜法除硝
50%烧碱
三效逆流
螯合树脂
membrane distance electrolyzer
sulfate removing technology by membrane method
50% causticsoda
three effect countercurrent
chelating resin