摘要
通过测量干式变压器的高压侧对低压侧、低压侧对高压侧及对地,铁芯对地绝缘电阻的变化与出厂绝缘电阻的比值变化及吸收比,来确认碘钨灯干燥法的效果。
Through measuring the insulation resistance change of the high vohage side to low vohage side and to the ground, the low voltage side to high vohage side and to ground, the iron core to the ground in dry - type transformer to ensure the effect of tungsten iodine lamp dehydration.
出处
《贵州电力技术》
2012年第8期60-62,64,共4页
Guizhou Electric Power Technology
关键词
干式变压器
水浸受潮
碘钨灯
热风
dry - type transformers
water leaching and wetting
tungsten iodine lamp
hot wind