期刊文献+

巢湖老城区排水管道健康状况的检测与评估 被引量:5

Inspection and assessment of drainage pipeline in old city zone of Chaohu
下载PDF
导出
摘要 巢湖老城区地下水位高,排水管道役龄长,管材陈旧,加之缺乏日常维护,造成管道排水效能差,污水处理厂进水浓度低。为最大限度地发挥管道排水能力,延长管道使用寿命,采用管道闭路电视检测及潜望镜检测技术,选取具有代表性的管段进行有效地检测和评估,掌握了管道运行的健康状况,并针对管道病害提出建议。 Due to the high level of underground water, long service time of pipeline, pipe material aging and lack of routine care or maintenance, the drainage efficiency of the pipeline was poor and the influent concentration of wastewater treatment plant was low. For the purpose of maximizing the drainage capability of the pipeline and prolonging its service life, closed circuit television and quickview technology were used to test and assess the performance of the representative pipeline sections. Finally, the operation status of the pipeline was dear, and then, some advises for solving the existing problems of the pipeline were given.
作者 王燕 黄明
出处 《工业用水与废水》 CAS 2012年第4期33-35,50,共4页 Industrial Water & Wastewater
基金 国家重大水专项基金资助项目(2009ZX07316-001)
关键词 排水管道 管道检测 管道闭路电视检测技术 潜望镜技术 drainage pipeline pipeline inspection closed circuit television technology quickview technology
  • 相关文献

参考文献5

  • 1李田,郑瑞东,朱军.排水管道检测技术的发展现状[J].中国给水排水,2006,22(12):11-13. 被引量:62
  • 2Reini Wirahadikusumah,Dulcy M Abraham,Tom Iseley,et al.Assessment technologies for sewer system rehabilitation[J].Automation in Construction,1998,7(4):259-270.
  • 3Eiwsirth M,Frey J Herbst C,Jaucbaseh A,et al.Sewer assess-ment by multi-sensor systems[M].Berlin:IWA2 World WaterCongress,2001.15-19.
  • 4Sanjiv Gokhal,Makarnad Hastak.Automated Assessment Techno-logies for Sanitary Sewer Evaluation[A].Proceedings of the ASCEInternational Conference on Pipeline Engineering and Construction:New Pipeline Technologies,Security and Safety[C].USA:ASCE,2003.560-570.
  • 5DB31/T444—2009,上海市公共排水管道电视和声纳检测评估技术规程[S].

二级参考文献5

  • 1Sinha Sunil K.State-of-the-art in sensor technologies for pipe inspection[A].Proceedings of the ASCE International Conference on Pipeline Engineering and Construction:New Pipeline Technologies,Security and Safety[C].Washington D C:ASCE,2003.
  • 2Reini Wirahadikusumah,Dulcy M Abraham,Tom Iseley,et al.Assessment technologies for sewer system rehabilitation[J].Autom in Construction,1998,7 (4):259 -270.
  • 3Sanjiv Gokhale,Jeffrey A Graham.A new development in locating leaks in sanitary sewers[J].Tunnelling and Underground Space Technology,2004,19 (2):85-96.
  • 4Eiswirth M,Frey C,Herbst J,et al.Sewer Assessment by Multi-sensor Systems[M].Berlin:IWA2 World Water Congress,2001.
  • 5Sinha Sunil K,Fieguth Paul W.Segmentation of buried concrete pipe images[J].Autom in Construction,2006,15(1):47 -57.