以1 400 mm单皮带栈桥为例,对比分析了石油化工企业封闭式输煤钢结构栈桥采用自动喷水灭火系统及水喷雾灭火系统的相关技术参数及用水量情况,常规状态下,结合皮带运动及水喷雾灭火系统动作快的特点,建议石油化工企业输煤栈桥水消防灭火系统采用水喷雾灭火系统。
Taking 1 400 mm single belt coal handling trestle as an example, the technical parameters and water consumption of automatic fire-extinguishing sprinkler system and water spray extinguishing system appliedfor closed steel coal handling trestle's fire-fighting in petrochemical enterprises were compared and analyzed. Under conventional condition, combined with the belt movement characteristics and the high flow speed of waterspray extinguishing system, water spray extinguishing system was suggested to be used for coal handling trestle's fire-fighting in petrochemical enterprises.
出处
《工业用水与废水》
CAS
2012年第4期82-84,共3页
Industrial Water & Wastewater
关键词
封闭式输煤钢结构栈桥
自动喷水灭火系统
水喷雾灭火系统
喷水强度
closed steel coal handling trestle
automatic fire-extinguishing sprinkler system
water spray extinguishing system