基于微小电流过采样的激光光栅测试系统 被引量:1

High-precision Laser Grating Test System Based on Little Current and Oversampling
下载PDF
导出
摘要 激光光栅的质量检测是光栅生产应用中的关键环节。该测试系统设计了高精度微小电流采样电路,采用过采样技术用AVR芯片内部10位ADC实现13位采样精度,采用窗口滤波、平均滤波进行进一步数据处理。系统提升光栅透光率的测量相对误差至5‰以内,0级与1级光斑光强比测量相对误差至1%以内,实现了高精度激光光栅测试。 The quality test of laser grating is the key in the production and application of grating.The test system designed high-precision little current sampling circuit.It adopted oversampling technique to achieve 13-bit sampling with a 10-bit ADC inside AVR MCU,and used window filtering and average filtering for further data processing.The system improves the relative error of grating’s transmittance to less than 5‰,and the ratio of the grade 1 to grade 0 to less than 1%,implements high-precision test for laser grating.
出处 《仪表技术与传感器》 CSCD 北大核心 2012年第8期35-38,共4页 Instrument Technique and Sensor
关键词 激光光栅 质量检测 微小电流 过采样 窗口滤波 laser grating quality test little current oversampling window filtering
  • 相关文献

参考文献5

二级参考文献6

共引文献10

同被引文献4

  • 1Deng Luogen resolution to study. Infrared and laser engi- neering grating laser vibrometer, 2001,(3): 67-69.
  • 2Jiang Yong; He Shaobo; Yuan Xiaodong; Wang Haijun; Li- ao Wei; Lv Haibing; Liu Chunming; Xiang Xia, Qiu Rong; Yang Yongjia; Zheng Wanguo; the experimental researches and numerical simulations of Zu Xiaotao.CO 2 laser scan- ning repair fused silica surface defects[J]. Journal of phys- ics, 2014, (06): 88-89.